Modify CI SA 60MHz 2x2 test to be DSUUU

Update configuration and tweak iperf thresholds accordingly. Tune some
parameters for good UL reception.
This commit is contained in:
Robert Schmidt
2025-09-11 19:47:52 +02:00
parent bb378620e9
commit 13e9910e4e
2 changed files with 15 additions and 12 deletions
@@ -24,6 +24,7 @@ gNBs =
pusch_AntennaPorts = 2; pusch_AntennaPorts = 2;
do_CSIRS = 1; do_CSIRS = 1;
do_SRS = 1; do_SRS = 1;
uess_agg_levels = [4,2,0,0,0];
servingCellConfigCommon = ( servingCellConfigCommon = (
{ {
@@ -139,9 +140,9 @@ gNBs =
# dl_UL_TransmissionPeriodicity # dl_UL_TransmissionPeriodicity
# 0=ms0p5, 1=ms0p625, 2=ms1, 3=ms1p25, 4=ms2, 5=ms2p5, 6=ms5, 7=ms10 # 0=ms0p5, 1=ms0p625, 2=ms1, 3=ms1p25, 4=ms2, 5=ms2p5, 6=ms5, 7=ms10
dl_UL_TransmissionPeriodicity = 5; dl_UL_TransmissionPeriodicity = 5;
nrofDownlinkSlots = 2; nrofDownlinkSlots = 1;
nrofDownlinkSymbols = 6; nrofDownlinkSymbols = 6;
nrofUplinkSlots = 2; nrofUplinkSlots = 3;
nrofUplinkSymbols = 4; nrofUplinkSymbols = 4;
ssPBCH_BlockPower = -20; ssPBCH_BlockPower = -20;
@@ -178,10 +179,12 @@ MACRLCs = (
num_cc = 1; num_cc = 1;
tr_s_preference = "local_L1"; tr_s_preference = "local_L1";
tr_n_preference = "local_RRC"; tr_n_preference = "local_RRC";
pusch_TargetSNRx10 = 300; pusch_TargetSNRx10 = 320;
pucch_TargetSNRx10 = 300; pucch_TargetSNRx10 = 320;
pusch_FailureThres = 100; pusch_FailureThres = 100;
ul_max_mcs = 28; ul_max_mcs = 28;
ul_bler_target_upper = 0.20;
ul_bler_target_lower = 0.10;
} }
); );
@@ -22,7 +22,7 @@
--> -->
<testCaseList> <testCaseList>
<htmlTabRef>TEST-SA-FR1-N310-2x2-60MHz</htmlTabRef> <htmlTabRef>TEST-SA-FR1-N310-2x2-60MHz</htmlTabRef>
<htmlTabName>60 MHz 2x2 TDD SA</htmlTabName> <htmlTabName>60 MHz 2x2 TDD SA DSUUU</htmlTabName>
<htmlTabIcon>tasks</htmlTabIcon> <htmlTabIcon>tasks</htmlTabIcon>
<TestCaseRequestedList> <TestCaseRequestedList>
100000 100000
@@ -114,8 +114,8 @@
<testCase id="071000"> <testCase id="071000">
<class>Iperf</class> <class>Iperf</class>
<desc>iperf (DL/200Mbps/UDP)(30 sec)(single-ue profile)</desc> <desc>iperf (DL/150Mbps/UDP)(30 sec)(single-ue profile)</desc>
<iperf_args>-u -b 200M -t 30 -R</iperf_args> <iperf_args>-u -b 150M -t 30 -R</iperf_args>
<svr_id>matix-cn5g</svr_id> <svr_id>matix-cn5g</svr_id>
<id>up2</id> <id>up2</id>
<iperf_packetloss_threshold>25</iperf_packetloss_threshold> <iperf_packetloss_threshold>25</iperf_packetloss_threshold>
@@ -124,8 +124,8 @@
<testCase id="071001"> <testCase id="071001">
<class>Iperf</class> <class>Iperf</class>
<desc>iperf (UL/180Mbps/UDP)(30 sec)(single-ue profile)</desc> <desc>iperf (UL/250Mbps/UDP)(30 sec)(single-ue profile)</desc>
<iperf_args>-u -b 180M -t 30</iperf_args> <iperf_args>-u -b 250M -t 30</iperf_args>
<svr_id>matix-cn5g</svr_id> <svr_id>matix-cn5g</svr_id>
<id>up2</id> <id>up2</id>
<iperf_packetloss_threshold>10</iperf_packetloss_threshold> <iperf_packetloss_threshold>10</iperf_packetloss_threshold>
@@ -147,8 +147,8 @@
<node>matix</node> <node>matix</node>
<yaml_path>ci-scripts/yaml_files/5g_sa_n310_2x2_60MHz</yaml_path> <yaml_path>ci-scripts/yaml_files/5g_sa_n310_2x2_60MHz</yaml_path>
<services>oai-gnb</services> <services>oai-gnb</services>
<d_retx_th>10,100,100,100</d_retx_th> <d_retx_th>15,100,100,100</d_retx_th>
<u_retx_th>10,100,100,100</u_retx_th> <u_retx_th>20,100,100,100</u_retx_th>
</testCase> </testCase>
<testCase id="333333"> <testCase id="333333">