Merge remote-tracking branch 'origin/fix-handover-doc' into integration_2026_w03 (!3788)
Fix handover documentation and configuration files for event configuration
This commit is contained in:
+28
-22
@@ -209,8 +209,8 @@ instead of waiting for UE measurement report.)
|
||||
Our CI setup consists of:
|
||||
- 2 USRPs B210 that are synchronized by connecting them to an Octoclock over
|
||||
10MHz refrence and a PPS signal. The RU hosts are synchronized via NTP.
|
||||
- Mini-Circuits RC4DAT-6G-60 programmable attenuator. To control the digital attenuator,
|
||||
a Python script was developed `ci-scripts/attenuatorctl.py`.
|
||||
- Mini-Circuits RC4DAT-6G-60 programmable attenuator. To control the digital
|
||||
attenuator, a Python script was developed `ci-scripts/attenuatorctl.py`.
|
||||
- Quectel RM520 as a UE.
|
||||
- The setup is run using Docker `ci-scripts/yaml_files/5g_sa_f1_b210_ho`.
|
||||
|
||||
@@ -241,14 +241,14 @@ The below configuration further enables periodic measurements, A2 event
|
||||
Better than Serving").
|
||||
The A2 event can be disabled by setting `enable = 0`.
|
||||
The A3 event cannot be disabled as of now. It can be made
|
||||
specific to cells or set to `cell_id = -1` which means "any cell".
|
||||
specific to cells or set to `physCellId = -1` which means "any cell".
|
||||
|
||||
`hysteresis` is a margin added to the serving cell measurements to
|
||||
prevent unnecessary or frequent handovers. It ensures that the neighbouring
|
||||
cell must show sufficiently better signal quality before a handover is
|
||||
triggered. It is an integer between 0 and 30.
|
||||
|
||||
`timeToTrigger` the time during which specific criteria for the event
|
||||
`time_to_trigger` the time during which specific criteria for the event
|
||||
needs to be met in order to trigger a measurement report. It is an enumerated
|
||||
parameter and in the configuration below it is set to 1 which corresponds to
|
||||
`ms40` or 40 milliseconds.
|
||||
@@ -312,23 +312,24 @@ nr_measurement_configuration = {
|
||||
};
|
||||
|
||||
A2 = {
|
||||
enable = 1;
|
||||
threshold = 60;
|
||||
timeToTrigger = 1;
|
||||
enable = 1;
|
||||
threshold = 60;
|
||||
time_to_trigger = 1;
|
||||
};
|
||||
|
||||
A3 = (
|
||||
{
|
||||
cell_id = -1;
|
||||
offset = 10;
|
||||
hysteresis = 0;
|
||||
timeToTrigger = 1;
|
||||
physCellId = -1;
|
||||
offset = 10;
|
||||
hysteresis = 0;
|
||||
time_to_trigger = 1;
|
||||
}
|
||||
)
|
||||
};
|
||||
```
|
||||
|
||||
`@include` this configuration file inside the gNB section of CU file as shown below.
|
||||
`@include` this configuration file inside the gNB section of CU file as shown
|
||||
below.
|
||||
|
||||
```
|
||||
plmn_list = ({ mcc = 001; mnc = 01; mnc_length = 2; snssaiList = ({ sst = 1, sd = 0xffffff })});
|
||||
@@ -390,7 +391,7 @@ are as follows:
|
||||
on UTC time or a timer-based solution, which can also be applied jointly (or
|
||||
not) with another trigger as the measurement-based trigger. The timer-based
|
||||
handover trigger considers the deterministic satellite movement to predict
|
||||
the time duration for which the satellite’s footprint covers a certain zone.
|
||||
the time duration for which the satellite's footprint covers a certain zone.
|
||||
|
||||
- **Timing advance value-based triggering**: This method uses the timing
|
||||
advance value (independently or jointly with another trigger) to trigger a
|
||||
@@ -432,14 +433,14 @@ We assume:
|
||||
|
||||
* Two independent gNBs connected to the same 5GC via N2 interface.
|
||||
* A UE initially connected to gNB-PCI0, which will be handed over to gNB-PCI1.
|
||||
* Handover is triggered by either a decision based measurement event (e.g. A3) or
|
||||
telnet command.
|
||||
* Handover is triggered by either a decision based measurement event (e.g. A3)
|
||||
or telnet command.
|
||||
|
||||
## Steps to run N2 handover with OAI UE
|
||||
|
||||
**Note for same-machine setup:** When running both gNBs on the same machine,
|
||||
you need to assign a unique IP address to the second gNB to avoid network conflicts.
|
||||
For example:
|
||||
you need to assign a unique IP address to the second gNB to avoid network
|
||||
conflicts. For example:
|
||||
|
||||
```sh
|
||||
sudo ip addr add 192.168.71.180/24 dev rfsim5g-public
|
||||
@@ -490,15 +491,20 @@ From gNB-PCI0, trigger handover on target gNB with PCI 1 for UE ID 1:
|
||||
```sh
|
||||
echo ci trigger_n2_ho 1,1 | nc 127.0.0.1 9090 && echo
|
||||
```
|
||||
where the input parameters correspond to the PCI of the neighbour cell and the RRC ID of the UE.
|
||||
where the input parameters correspond to the PCI of the neighbor cell and the
|
||||
RRC ID of the UE.
|
||||
|
||||
This will initiate the N2 handover on the source gNB.
|
||||
|
||||
## Neighbour list and measurement configuration
|
||||
|
||||
Make sure the configuration file contains a neighbour list and measurement configuration, e.g. [neighbour-config-rfsim.conf](../../ci-scripts/conf_files/neighbour-config.conf).
|
||||
This configuration can also be present in a different file and included in the gNB configuration file with `@include "neighbour-config-rfsim.conf"`.
|
||||
Make sure the configuration file contains a neighbour list and measurement
|
||||
configuration, e.g. [neighbour-config-rfsim.conf](../../ci-scripts/conf_files/neighbour-config.conf).
|
||||
This configuration can also be present in a different file and included in the
|
||||
gNB configuration file with `@include "neighbour-config-rfsim.conf"`.
|
||||
|
||||
For each gNB there is a `neighbour_cell_configuration` linked to its serving cell ID.
|
||||
For each gNB there is a `neighbour_cell_configuration` linked to its serving
|
||||
cell ID.
|
||||
|
||||
See the example above for `neighbour-config-ho.conf`. The same configuration is for both F1 and N2 handover.
|
||||
See the example above for `neighbour-config-ho.conf`. The same configuration
|
||||
is for both F1 and N2 handover.
|
||||
|
||||
Reference in New Issue