NR UE: set time sync PI controller integral weight to 0.0 by default
Experiments did show that the time sync is less stable in terrestrial mode if the integral part of the PI controller is used. So set it to 0.0 by default. For NTN LEO use case we can still use it by providing the command line parameter --time-sync-I 0.2 . fixes #846
This commit is contained in:
+1
-1
@@ -298,7 +298,7 @@ Also, to perform an autonomous TA update based on the DL drift, the boolean para
|
||||
So an example NR UE command for FDD, 5MHz BW, 15 kHz SCS, transparent LEO satellite 5G NR NTN is this:
|
||||
```
|
||||
cd cmake_targets
|
||||
sudo ./ran_build/build/nr-uesoftmodem --band 66 -C 2152680000 --CO -400000000 -r 25 --numerology 0 --ssb 48 --sa --rfsim --rfsimulator.prop_delay 20 --rfsimulator.options chanmod -O ../targets/PROJECTS/GENERIC-NR-5GC/CONF/channelmod_rfsimu_LEO_satellite.conf --ntn-koffset 40 --ntn-ta-common 37.74 --ntn-ta-commondrift -50 --autonomous-ta
|
||||
sudo ./ran_build/build/nr-uesoftmodem --band 66 -C 2152680000 --CO -400000000 -r 25 --numerology 0 --ssb 48 --sa --rfsim --rfsimulator.prop_delay 20 --rfsimulator.options chanmod -O ../targets/PROJECTS/GENERIC-NR-5GC/CONF/channelmod_rfsimu_LEO_satellite.conf --time-sync-I 0.2 --ntn-koffset 40 --ntn-ta-common 37.74 --ntn-ta-commondrift -50 --autonomous-ta
|
||||
```
|
||||
|
||||