Remove AutoTerminateUEeNB() functions, use auto_exec to make CI always undeploy
This commit is contained in:
@@ -293,7 +293,7 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue('N/A', 'OK', messages)
|
||||
return True
|
||||
|
||||
def AttachUE(self, HTML, RAN, EPC, CONTAINERS):
|
||||
def AttachUE(self, HTML):
|
||||
ues = [cls_module.Module_UE(ue_id, server_name) for ue_id, server_name in zip(self.ue_ids, self.nodes)]
|
||||
with concurrent.futures.ThreadPoolExecutor(max_workers=64) as executor:
|
||||
futures = [executor.submit(ue.attach) for ue in ues]
|
||||
@@ -307,7 +307,6 @@ class OaiCiTest():
|
||||
else:
|
||||
logging.error(f'error attaching or wrong MTU: attached {attached}, mtus {mtus}')
|
||||
HTML.CreateHtmlTestRowQueue('N/A', 'KO', ["Could not retrieve UE IP address(es) or MTU(s) wrong!"])
|
||||
self.AutoTerminateUEandeNB(HTML, RAN, EPC, CONTAINERS)
|
||||
return success
|
||||
|
||||
def DetachUE(self, HTML):
|
||||
@@ -358,7 +357,7 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue('NA', 'OK', messages)
|
||||
return True
|
||||
|
||||
def Ping_common(self, EPC, ue, RAN, logPath):
|
||||
def Ping_common(self, EPC, ue, logPath):
|
||||
# Launch ping on the EPC side (true for ltebox and old open-air-cn)
|
||||
ping_status = 0
|
||||
ueIP = ue.getIP()
|
||||
@@ -429,7 +428,7 @@ class OaiCiTest():
|
||||
|
||||
return (True, message)
|
||||
|
||||
def Ping(self,HTML,RAN,EPC,CONTAINERS):
|
||||
def Ping(self, HTML, EPC, CONTAINERS):
|
||||
if EPC.IPAddress == '' or EPC.UserName == '' or EPC.Password == '' or EPC.SourceCodePath == '':
|
||||
HELP.GenericHelp(CONST.Version)
|
||||
sys.exit('Insufficient Parameter')
|
||||
@@ -444,7 +443,7 @@ class OaiCiTest():
|
||||
ues = [cls_module.Module_UE(ue_id, server_name) for ue_id, server_name in zip(self.ue_ids, self.nodes)]
|
||||
logging.debug(ues)
|
||||
with concurrent.futures.ThreadPoolExecutor(max_workers=64) as executor:
|
||||
futures = [executor.submit(self.Ping_common, EPC, ue, RAN, logPath) for ue in ues]
|
||||
futures = [executor.submit(self.Ping_common, EPC, ue, logPath) for ue in ues]
|
||||
results = [f.result() for f in futures]
|
||||
# each result in results is a tuple, first member goes to successes, second to messages
|
||||
successes, messages = map(list, zip(*results))
|
||||
@@ -463,10 +462,9 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue(self.ping_args, 'OK', messages)
|
||||
else:
|
||||
HTML.CreateHtmlTestRowQueue(self.ping_args, 'KO', messages)
|
||||
self.AutoTerminateUEandeNB(HTML,RAN,EPC,CONTAINERS)
|
||||
return success
|
||||
|
||||
def Iperf_Module(self, EPC, ue, svr, RAN, idx, ue_num, logPath):
|
||||
def Iperf_Module(self, EPC, ue, svr, idx, ue_num, logPath):
|
||||
ueIP = ue.getIP()
|
||||
if not ueIP:
|
||||
return (False, f"UE {ue.getName()} has no IP address")
|
||||
@@ -512,7 +510,7 @@ class OaiCiTest():
|
||||
|
||||
return (status, f'{ue_header}\n{msg}')
|
||||
|
||||
def Iperf(self,HTML,RAN,EPC,CONTAINERS):
|
||||
def Iperf(self,HTML,EPC,CONTAINERS):
|
||||
if EPC.IPAddress == '' or EPC.UserName == '' or EPC.Password == '' or EPC.SourceCodePath == '':
|
||||
HELP.GenericHelp(CONST.Version)
|
||||
sys.exit('Insufficient Parameter')
|
||||
@@ -530,7 +528,7 @@ class OaiCiTest():
|
||||
svr = cls_module.Module_UE(self.svr_id,self.svr_node)
|
||||
logging.debug(ues)
|
||||
with concurrent.futures.ThreadPoolExecutor(max_workers=64) as executor:
|
||||
futures = [executor.submit(self.Iperf_Module, EPC, ue, svr, RAN, i, len(ues), logPath) for i, ue in enumerate(ues)]
|
||||
futures = [executor.submit(self.Iperf_Module, EPC, ue, svr, i, len(ues), logPath) for i, ue in enumerate(ues)]
|
||||
results = [f.result() for f in futures]
|
||||
# each result in results is a tuple, first member goes to successes, second to messages
|
||||
successes, messages = map(list, zip(*results))
|
||||
@@ -549,10 +547,9 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue(self.iperf_args, 'OK', messages)
|
||||
else:
|
||||
HTML.CreateHtmlTestRowQueue(self.iperf_args, 'KO', messages)
|
||||
self.AutoTerminateUEandeNB(HTML,RAN,EPC,CONTAINERS)
|
||||
return success
|
||||
|
||||
def Iperf2_Unidir(self,HTML,RAN,EPC,CONTAINERS):
|
||||
def Iperf2_Unidir(self,HTML,EPC,CONTAINERS):
|
||||
if self.ue_ids == [] or self.svr_id == None or len(self.ue_ids) != 1:
|
||||
raise Exception("no module names in self.ue_ids or/and self.svr_id provided, multi UE scenario not supported")
|
||||
ue = cls_module.Module_UE(self.ue_ids[0].strip(),self.nodes[0].strip())
|
||||
@@ -590,7 +587,6 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue(self.iperf_args, 'OK', [f'{ue_header}\n{msg}'])
|
||||
else:
|
||||
HTML.CreateHtmlTestRowQueue(self.iperf_args, 'KO', [f'{ue_header}\n{msg}'])
|
||||
self.AutoTerminateUEandeNB(HTML,RAN,EPC,CONTAINERS)
|
||||
return success
|
||||
|
||||
def AnalyzeLogFile_UE(self, UElogFile,HTML,RAN):
|
||||
@@ -874,62 +870,6 @@ class OaiCiTest():
|
||||
HTML.CreateHtmlTestRowQueue(f'N/A', 'OK', messages)
|
||||
return True
|
||||
|
||||
def AutoTerminateUEandeNB(self,HTML,RAN,EPC,CONTAINERS):
|
||||
if (RAN.Initialize_eNB_args != ''):
|
||||
self.testCase_id = 'AUTO-KILL-RAN'
|
||||
HTML.testCase_id = self.testCase_id
|
||||
self.desc = 'Automatic Termination of all RAN nodes'
|
||||
HTML.desc = self.desc
|
||||
self.ShowTestID()
|
||||
#terminate all RAN nodes eNB/gNB/OCP
|
||||
for instance in range(0, len(RAN.air_interface)):
|
||||
if RAN.air_interface[instance]!='':
|
||||
logging.debug(f'Auto Termination of Instance {instance} : {RAN.air_interface[instance]}')
|
||||
RAN.eNB_instance=instance
|
||||
RAN.TerminateeNB(HTML,EPC)
|
||||
if CONTAINERS.yamlPath[0] != '':
|
||||
self.testCase_id = 'AUTO-KILL-CONTAINERS'
|
||||
HTML.testCase_id = self.testCase_id
|
||||
self.desc = 'Automatic Termination of all RAN containers'
|
||||
HTML.desc = self.desc
|
||||
self.ShowTestID()
|
||||
for instance in range(0, len(CONTAINERS.yamlPath)):
|
||||
if CONTAINERS.yamlPath[instance]!='':
|
||||
CONTAINERS.eNB_instance=instance
|
||||
if CONTAINERS.deployKind[instance]:
|
||||
CONTAINERS.UndeployObject(HTML,RAN)
|
||||
else:
|
||||
CONTAINERS.UndeployGenObject(HTML,RAN, self)
|
||||
|
||||
#this function is called only if eNB/gNB fails to start
|
||||
#RH to be re-factored
|
||||
def AutoTerminateeNB(self,HTML,RAN,EPC,CONTAINERS):
|
||||
if (RAN.Initialize_eNB_args != ''):
|
||||
self.testCase_id = 'AUTO-KILL-RAN'
|
||||
HTML.testCase_id = self.testCase_id
|
||||
self.desc = 'Automatic Termination of all RAN nodes'
|
||||
HTML.desc = self.desc
|
||||
self.ShowTestID()
|
||||
#terminate all RAN nodes eNB/gNB/OCP
|
||||
for instance in range(0, len(RAN.air_interface)):
|
||||
if RAN.air_interface[instance]!='':
|
||||
logging.debug(f'Auto Termination of Instance {instance} : {RAN.air_interface[instance]}')
|
||||
RAN.eNB_instance=instance
|
||||
RAN.TerminateeNB(HTML,EPC)
|
||||
if CONTAINERS.yamlPath[0] != '':
|
||||
self.testCase_id = 'AUTO-KILL-CONTAINERS'
|
||||
HTML.testCase_id = self.testCase_id
|
||||
self.desc = 'Automatic Termination of all RAN containers'
|
||||
HTML.desc = self.desc
|
||||
self.ShowTestID()
|
||||
for instance in range(0, len(CONTAINERS.yamlPath)):
|
||||
if CONTAINERS.yamlPath[instance]!='':
|
||||
CONTAINERS.eNB_instance=instance
|
||||
if CONTAINERS.deployKind[instance]:
|
||||
CONTAINERS.UndeployObject(HTML,RAN)
|
||||
else:
|
||||
CONTAINERS.UndeployGenObject(HTML,RAN,self)
|
||||
|
||||
def LogCollectBuild(self,RAN):
|
||||
# Some pipelines are using "none" IP / Credentials
|
||||
# In that case, just forget about it
|
||||
|
||||
Reference in New Issue