NR_UE: always break out of MAC PDU processing after pdu_len Bytes
In case of false positive PDSCH CRC check, a random MAC PDU is processed. Currently pdu_len is unsigned 16 Bit, so we did break out of the processing loop only if we _exactly_ hit a residual pdu_len of 0, or we hit a LCID of DL_SCH_LCID_PADDING. If we didn't hit either of these, pdu_len wrapped to a very positive value, and we continued processing the PDU even beyond its bounds! This behavior was observed with SNR 1 dB and MCS 9. So better make pdu_len signed and break out of the loop after processing at max. pdu_len Bytes!
This commit is contained in:
@@ -881,7 +881,7 @@ void nr_ue_dlsch_procedures(PHY_VARS_NR_UE *ue,
|
||||
int harq_pid = dlsch0->current_harq_pid;
|
||||
int frame_rx = proc->frame_rx;
|
||||
int nr_slot_rx = proc->nr_slot_rx;
|
||||
int ret=0, ret1=0;
|
||||
uint32_t ret = UINT32_MAX, ret1 = UINT32_MAX;
|
||||
NR_UE_PDSCH *pdsch_vars;
|
||||
uint16_t dmrs_len = get_num_dmrs(dlsch0->harq_processes[dlsch0->current_harq_pid]->dlDmrsSymbPos);
|
||||
nr_downlink_indication_t dl_indication;
|
||||
|
||||