[CI][Docker] able to deploy/undeploy a monolithic eNB with a compose file:
-- The compose file still keeps a few template fields to be replaced -- initial scenario has a full UE attach / traffic test Signed-off-by: Raphael Defosseux <raphael.defosseux@eurecom.fr>
This commit is contained in:
+24
-3
@@ -310,6 +310,22 @@ def GetParametersFromXML(action):
|
||||
if (string_field is not None):
|
||||
EPC.yamlPath = string_field
|
||||
|
||||
elif action == 'Deploy_Object' or action == 'Undeploy_Object':
|
||||
eNB_instance=test.findtext('eNB_instance')
|
||||
if (eNB_instance is None):
|
||||
CONTAINERS.eNB_instance=0
|
||||
else:
|
||||
CONTAINERS.eNB_instance=int(eNB_instance)
|
||||
eNB_serverId=test.findtext('eNB_serverId')
|
||||
if (eNB_serverId is None):
|
||||
CONTAINERS.eNB_serverId[CONTAINERS.eNB_instance]='0'
|
||||
else:
|
||||
CONTAINERS.eNB_serverId[CONTAINERS.eNB_instance]=eNB_serverId
|
||||
string_field = test.findtext('yaml_path')
|
||||
if (string_field is not None):
|
||||
CONTAINERS.yamlPath[CONTAINERS.eNB_instance] = string_field
|
||||
|
||||
|
||||
else: # ie action == 'Run_PhySim':
|
||||
ldpc.runargs = test.findtext('physim_run_args')
|
||||
|
||||
@@ -368,6 +384,7 @@ RAN.htmlObj=HTML
|
||||
RAN.epcObj=EPC
|
||||
CONTAINERS.htmlObj=HTML
|
||||
CONTAINERS.epcObj=EPC
|
||||
CONTAINERS.ranObj=RAN
|
||||
|
||||
|
||||
ldpc=cls_physim.PhySim() #create an instance for LDPC test using GPU or CPU build
|
||||
@@ -591,7 +608,7 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
|
||||
logging.debug('ERROR: requested test is invalidly formatted: ' + test)
|
||||
sys.exit(1)
|
||||
if (EPC.IPAddress != '') and (EPC.IPAddress != 'none'):
|
||||
CiTestObj.CheckFlexranCtrlInstallation(RAN,EPC)
|
||||
CiTestObj.CheckFlexranCtrlInstallation(RAN,EPC,CONTAINERS)
|
||||
EPC.SetMmeIPAddress()
|
||||
|
||||
#get the list of tests to be done
|
||||
@@ -652,8 +669,6 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
|
||||
break
|
||||
if action == 'Build_eNB':
|
||||
RAN.BuildeNB()
|
||||
elif action == 'Build_Image':
|
||||
CONTAINERS.BuildImage()
|
||||
elif action == 'WaitEndBuild_eNB':
|
||||
RAN.WaitBuildeNBisFinished()
|
||||
elif action == 'Initialize_eNB':
|
||||
@@ -729,6 +744,12 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
|
||||
if ldpc.exitStatus==1:sys.exit()
|
||||
elif action == 'Run_PhySim':
|
||||
HTML=ldpc.Run_PhySim(HTML,CONST,id)
|
||||
elif action == 'Build_Image':
|
||||
CONTAINERS.BuildImage()
|
||||
elif action == 'Deploy_Object':
|
||||
CONTAINERS.DeployObject()
|
||||
elif action == 'Undeploy_Object':
|
||||
CONTAINERS.UndeployObject()
|
||||
else:
|
||||
sys.exit('Invalid class (action) from xml')
|
||||
if not RAN.prematureExit:
|
||||
|
||||
Reference in New Issue