fix: use correct variables' names
- timeToTrigger must be named time_to_trigger - cell_id must be named physCellId
This commit is contained in:
@@ -241,14 +241,14 @@ The below configuration further enables periodic measurements, A2 event
|
|||||||
Better than Serving").
|
Better than Serving").
|
||||||
The A2 event can be disabled by setting `enable = 0`.
|
The A2 event can be disabled by setting `enable = 0`.
|
||||||
The A3 event cannot be disabled as of now. It can be made
|
The A3 event cannot be disabled as of now. It can be made
|
||||||
specific to cells or set to `cell_id = -1` which means "any cell".
|
specific to cells or set to `physCellId = -1` which means "any cell".
|
||||||
|
|
||||||
`hysteresis` is a margin added to the serving cell measurements to
|
`hysteresis` is a margin added to the serving cell measurements to
|
||||||
prevent unnecessary or frequent handovers. It ensures that the neighbouring
|
prevent unnecessary or frequent handovers. It ensures that the neighbouring
|
||||||
cell must show sufficiently better signal quality before a handover is
|
cell must show sufficiently better signal quality before a handover is
|
||||||
triggered. It is an integer between 0 and 30.
|
triggered. It is an integer between 0 and 30.
|
||||||
|
|
||||||
`timeToTrigger` the time during which specific criteria for the event
|
`time_to_trigger` the time during which specific criteria for the event
|
||||||
needs to be met in order to trigger a measurement report. It is an enumerated
|
needs to be met in order to trigger a measurement report. It is an enumerated
|
||||||
parameter and in the configuration below it is set to 1 which corresponds to
|
parameter and in the configuration below it is set to 1 which corresponds to
|
||||||
`ms40` or 40 milliseconds.
|
`ms40` or 40 milliseconds.
|
||||||
@@ -312,17 +312,17 @@ nr_measurement_configuration = {
|
|||||||
};
|
};
|
||||||
|
|
||||||
A2 = {
|
A2 = {
|
||||||
enable = 1;
|
enable = 1;
|
||||||
threshold = 60;
|
threshold = 60;
|
||||||
timeToTrigger = 1;
|
time_to_trigger = 1;
|
||||||
};
|
};
|
||||||
|
|
||||||
A3 = (
|
A3 = (
|
||||||
{
|
{
|
||||||
cell_id = -1;
|
physCellId = -1;
|
||||||
offset = 10;
|
offset = 10;
|
||||||
hysteresis = 0;
|
hysteresis = 0;
|
||||||
timeToTrigger = 1;
|
time_to_trigger = 1;
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
};
|
};
|
||||||
|
|||||||
Reference in New Issue
Block a user