4 Commits
Author SHA1 Message Date
Bartosz Podrygajlo 4ebe910363 Add extra cache for imscope record thread
This should allow to capture UE time domain data after PDSCH decoding failure.
2025-06-03 11:46:23 +02:00
Bartosz Podrygajlo 2ea6ac26bd Use a global "void_instruction" in imscope record thread
This avoids the issue of compare_exchange_weak always failing. The issue
was that `store()` is not equal to `exchange()`. `exchange` uses memory
copy while `store()` copies the value representation of the argument, which
is not always the same thing.
2025-01-28 16:55:53 +01:00
Bartosz Podrygajlo 2198e31187 More updates to imscope IQ recorder
- Added event parameter for recording which is reflected in the filename
 - Added event in the UE for DLSCH NACK
 - Added program name to the filename for ease of identification
 - Reworked spinlock to use atomics
2025-01-28 16:55:25 +01:00
Bartosz Podrygajlo ab75a7ccfb Add IQ file recording and IQ file viewer to ImScope
This commit introduces the following changes to ImScope:
 - Added the ability to record IQ data using the same mechanism as ImScope.
 - Added a new executable target `imscope_iq_file_viewer` for viewing IQ files.
 - Introduced a command line argument `--imscope-record` that enables data recording mode.
 - Refactored a lot of the scope code

Usage:
 - To record IQ data, run a modem with `--imscope-record` flag.
   The recording happens whenever a modem calls dumpScopeData, which currently is
   done only in gNB on PUSCH DTX and PUSCH CRC NOK.
   There is a limit of ~1GB of files written by the thread in a signle run to avoid
   accidentally exhausting disk space.
   If a directory `imscope-dump` is available the data will be recorded there in .imscope
   files. Otherwise files are written to the directory the modem was run. This is done so that
   the directory can be mapped in a docker container.

 - To view recorded IQ files, use the new executable `imscope_iq_file_viewer`. This can be done by running:
      ```
      ./imscope_iq_file_viewer <path_to_iq_file>
      ```
   Replace `<path_to_iq_file>` with the path to the IQ file you want to view.
2025-01-28 16:54:54 +01:00