The test was actually never executed correctly (unsigned -10 is never <= 10), and log2_approx64_ref() was not accurate enough.
Therefore replace it by directly comparing one value above and one value below each rounding boundary.
To skip the test, we use the gtest command line parameter "--gtest_filter" to filter out the unwanted test.
This parameter is described as follows:
--gtest_filter=POSITIVE_PATTERNS[-NEGATIVE_PATTERNS]
Run only the tests whose name matches one of the positive patterns but
none of the negative patterns. '?' matches any single character; '*'
matches any substring; ':' separates two patterns.
See e.g., egrep(1) [https://linux.die.net/man/1/egrep]:
> two variant programs egrep and fgrep are available. egrep is the same
> as grep -E. fgrep is the same as grep -F. Direct invocation as either
> egrep or fgrep is deprecated
See also the rationale of the POSIX description of grep
(https://pubs.opengroup.org/onlinepubs/9699919799/utilities/grep.html):
> This grep has been enhanced in an upwards-compatible way to provide
> the exact functionality of the historical egrep and fgrep commands as
> well. It was the clear intention of the standard developers to
> consolidate the three greps into a single command.
Closes: #839
Mapping of data REs in DMRS symbol depends only on number of CDM group
no data. So the special case function that depended on delta is removed
and a single function is used.
- Better trace DLSCH decoding result
- Rename the decode result variable to separate with later ack/nack
encode of this decoding result from 3GPP (not trivial true=1 coding)
- Cleanup decodeResult usage
- Remove unused defines
Co-authored-by: Francesco Mani <email@francescomani.it>
pdschRxdataF_comp data source was handled incorrectly. Each symbol entire slot data was copied. This
caused pdschRxdataF_comp to mostly contain zeros. The call to UEscopeCopy was moved from symbol loop
into last symbol processing. In case imscope is used padding and unused REs are not copied to the
sink.