This change updates the NSA-B200 CI pipeline to guarantee that the EPC is
properly terminated regardless of pipeline success or failure. This avoids
leaving EPC processes running after failed test.
PDU Session Release
This MR implements end-to-end PDU Session Release functionality
according to 3GPP TS 38.413 and TS 38.331 specifications.
Reason for Change Previous implementation had incomplete and wrongly
places tunnel cleanup during PDU session release. UP cleanup shall be
done at CUUP, RRCReconfiguration shall be sent after retrieval of
updated CellGroupConfig from the DU. This implies F1 and E1 exchanges
during PDU session release procedure.
Major Changes:
1. RRC PDU Session Release: DRBs and PDU session teardown in NGAP PDU
Session Release Response callback
- Helper Functions: Introduced rm_pduSession,
find_drb_by_pdusession_id and rm_drbs() helpers to locate and clean
up DRBs linked to a specific PDU session
- Targeted Cleanup: RRC PDU Session and per-session DRB removal in
rrc_gNB_send_NGAP_PDUSESSION_RELEASE_RESPONSE()
- Status Cleanup: Removed unused PDU_SESSION_STATUS_RELEASED status
2. RRC PDU Session Release: Refactor
rrc_gNB_process_NGAP_PDUSESSION_RELEASE_COMMAND
- Any PDU session in the pdusession_release_params list that is
present in the RRC list can be set to release, regardless of its
status
- Function Signature Update: Updated function signature and other
minor changes
- Response Handling: rrc_gNB_send_NGAP_PDUSESSION_RELEASE_RESPONSE is
sent upon completion of RRCReconfiguration
3. RRC PDU Session Release: add missing procedures E1AP Integration:
- Populates E1AP Bearer Modification for each to be released session
- PDCP Enhancement: Added nr_pdcp_release_drbs() to remove all DRBs
linked to a given PDU session in CUUP
- GTP-U Cleanup: GTP tunnel teardown handled in CUUP
e1_bearer_context_modif() using correct F1 or N3 GTP instance
4. NR PDCP/GTP:
- Enhanced Tunnel Deletion Logic: Separate handling for N3 tunnels (1
per PDU session) and F1-U tunnels (1 per DRB)
- New PDCP API Function: Added nr_pdcp_get_drb_ids_for_pdusession()
function to retrieve all DRB IDs associated with a specific PDU
session
5. RRC PDU Session Release: F1AP-based UE Context Modification:
- Replaced direct RRC message transfer with F1AP UE Context
Modification Request for proper retrieval from DU
- Cell Group Configuration: handling of updated CellGroupConfig from
DU ensures DRB release at CU
6. Docs and testing:
- Added PDU session add/remove test cases to 25 PRB RFSIM pipeline
- Documentation: Added PDU Session Release sequence diagram
- Telnet Commands: Added ci command to trigger NGAP PDU Session
Release and ciUE command to trigger establishment of a new PDU
Session
7. Additional fixes:
- UE RLC Management: ensure release of RLC entities
- Unify NG delay control before calling the RRC NGAP handler, for both
Setup and Release
8. Code Cleanup: Cleaned up unused GTP teardown functions.
Closes#867
- Enable telnet server on VNF (gNB) and UE in docker-compose.yaml
- Add new test cases for PDU session management:
* Add PDU session via UE telnet
* Release PDU session via telnet
* Verify connectivity after PDU session release
- Integrate telnet commands into existing container_5g_rfsim_u0_25prb.xml pipeline
- Test cases added before undeploy step in proper execution order
[MAC] Add UL total/used aggregated MAC stats; [E2 agent] Properly calculate
used UE PRBs in KPM; [CI] Simplify and improve the Undeploy_Object() and
implement Stop_Object()
- Create common dlul_mac_stats_t struct for both DL and UL total/used aggregated
PRBs
- Use correct unit [%] for RRU.PrbTotDl and RRU.PrbTotUl , instead of [PRBs]
- Use correct unit [Mb] for DRB.PdcpSduVolumeDL and DRB.PdcpSduVolumeUL [kb]
- Implement Stop_Object() (docker compose stop = SIGTERM)
- Simplify the Undeploy_Object() function
- Improve the logging for Deploy/Undeploy_Object() functions
- OAI-FlexRIC CI: properly stop all the containers (one by one or a subgroup of
running containers), and rename oai-flexric to nearRT-RIC container
1. Rename oai-flexric to nearRT-RIC. FlexRIC is a project combining nearRT-RIC, xApps, and E2 agent emulators.
2. Instead of undeploying all the containers at the same time, and not checking the logs for xApps and nearRT-RIC, do the following:
- Stop containers (docker compose stop) - one or subgroup of running containers in the following order:
a) xapp-kpm-moni
b) xapp-kpm-rc
c) xapp-gtp-mac-rlc-pdcp-moni
d) oai-nr-ue oai-nr-ue2
e) oai-gnb
f) nearRT-RIC
- Undeploy containers (docker compose down), collect and analyze all the logs.
PRS bug fix and CI Integration
- Fix the bug in PRS channel estimation while copying memory to compute the
impulse response
- Integrate PRS testing to CI
Some CI tasks/commands like Iperf(), Ping() get multiple nodes (via XML
parameter "nodes") to potentially run UEs on different nodes (hosts) at
the same time. However, I argue that this is not good:
- we don't actually use this -- where we specify multiple UEs, it's
always "localhost localhost..."
- it is inconsistent, as we typically have a single "node", not nodes,
and there is a possibility to harmonize (see also next commit)
- if we needed it, there would be better ways to achieve the same.
First, for hardware-based UEs, the ci_infra.yaml can specify different
UEs. For simulated UEs, it would be feasible to have multiple XML
steps run in parallel, e.g., in the XML <parallel> tag, which would
clarify that multiple UEs on different hosts run in parallel
- it reduces code.
Hence, make a single <node> for these XML steps.
CI: ensure clean iperf3 server startup
- Resolves issue with iperf3 test failure in RFSim5G multiue test
- Minor fix of iperf3 test descriptions in RFSim5G pipeline
- Add XML pipeline for N2 handover testing
- Add Docker compose for two monolithic gNBs
- Features:
* Two monolithic gNBs (gNB1, gNB2) with proper CU+DU parameters
* Gradual attenuation control using RC4DAT attenuator (5s duration)
* N2 handover sequence: gNB1 → gNB2 → gNB1
* Proper channel mapping: ch1-2 for gNB1, ch3-4 for gNB2
* Telnet server configuration for CI commands
* Handover-specific neighbor configuration
* Clean test state management with attenuator reset
By configuring the Jenkins pythonExecutor to match the test machine, we can use
localhost as the node for running individual test cases. This change makes it
easy to move tests across machines, as the only adjustment needed is updating
the pythonExecutor in Jenkins.
By configuring the Jenkins pythonExecutor to match the test machine, we can use
localhost as the node for running individual test cases. This change makes it
easy to move tests across machines, as the only adjustment needed is updating
the pythonExecutor in Jenkins.
By configuring the Jenkins pythonExecutor to match the test machine, we can use
localhost as the node for running individual test cases. This change makes it
easy to move tests across machines, as the only adjustment needed is updating
the pythonExecutor in Jenkins.
CI: Upgrade HO setup to use an attenuator
The goal of this MR is to upgrade HO CI setup to include a digital attenuator
that will allow us to trigger handover by attenuating the signals on the DUs.
- Trigger handover
- IdleSleep 2s
- Ping ext-dn from NR-UE
- Verify UE(1) connected to DU-PCI1
Validate absence of heap-use-after-free ASAN error found in !3600.
Closes#940
The next commit introduces an "UL-heavy" configuration to be tested with
Aerial. To avoid waiting for the CN, start&stop it once at the beginning
of the CI run.
Reduce throughput requirement, as this fails once two DUs are connected
to a UE, which creates more load on the machine and frequently fails
with low throughput.
CI: Enable Physim threshold check for tests on Caracal and GH
This MR adds support for configurable timing threshold files in PhySim
tests.
- Introduces a new CMake cache variable PHYSIM_CHECK_FILES to specify
one or more timing threshold files (semicolon-separated).
- Enables optional enforcement of timing thresholds check in PhySim
tests without changing existing test definitions.
- Defines timing thresholds for LDPC encoding/decoding in nr_ulsim,
nr_dlsim and ldpctest on Caracal and GH machines.
Add OAIUE longrun pipeline
Add a new XML file for OAIUE longrun.
- Test description:
* 40 MHz BW, n78
* gNB with USRP N310, UE with USRP N310
* CN deployed on OC
- Test duration: 1 hour
- Test scenario: 3x DL 10 min test (20 Mbps) + 3x UL 10 min test (5
Mbps)
- Remove extensive traffic testing before HO (iperf tests 030001, 030002)
- Do 1 ping test after attachment
- Reduce ping packet count from 100 to 50 packets for remaining connectivity test
Time savings: ~2-3 minutes by removing traffic validation overhead
N2 handover
This MR introduces full support for N2 handover, covering handover
decision, preparation, execution, and notification between source and
target NG-RAN nodes.
Key features:
1. Handover Decision & Preparation:
- Implement N2 handover decision based on UE measurement reports.
- Generate the Handover Preparation Information message, including
RRCReconfiguration.
- Send Handover Required message from the source NG-RAN to the AMF.
2. Handover Execution:
- Decode and handle the Handover Request on the target NG-RAN.
- Process the Handover Command on the source gNB, triggering
RRCReconfiguration.
- Initiate Handover Notify after successful completion.
3 NGAP & RRC Enhancements:
- Implement NGAP encoding/decoding functions for Handover Required,
Handover Request, Handover Command, Handover Failure, and Handover
Notify (3GPP TS 38.413).
- Adds NG-RAN Status Transfer support (UL/DL) for PDCP COUNT
preservation during mobility:
- support for NGAP Uplink and Downlink RAN Status Transfer messages
(TS 38.413 §9.2.3.13-14) to enable proper PDCP COUNT value
transfer during handover or recovery: NGAP encoding/decoding for
RAN Status Transfer, PDCP helpers to extract and apply COUNT (HFN
+ SN) per DRB. This aligns with TS 38.300 §9.2.3.2.1 and TS 23.502
§4.9.1.3.3, ensuring PDCP status preservation in AM.
4. Testing:
- Introduce a Telnet command to manually trigger N2 handover using UE
ID and neighbor PCI.
- Add configuration file for testing N2 handover with a target gNB.
The pipeline is using the already existing conf files
for the source/target gNB CUs/DUs.
For the sake of simplicity, neighbour-config.conf has
been rewritten and simplified in this commit, then
adopted in this pipeline. The file was not used before.
For clarity, rename to native_armv9 for clarity. The check inside Python
checked for native_arm, and if we introduce native_armv8 (for jetson),
it would also match that.
CI: Generalize PhySim tests, run PhySims on Gracehopper
This changeset generalizes/harmonizes the CI infrastructure for physim
testing, and adds a new pipeline for physim tests on Gracehopper
machines.
Specifically:
- Refactor the existing CI code for running and analyzing physical
simulators. The existing code assumed those tests are deployed using
OpenShift. Instead, OpenShift/Helm-specificities (e.g., running a
"release") have been removed, and instead of hardcoding the deployment
of the physical simulators using a script for Helm, the function takes
any script that can deploy using Helm/docker/from source. The overall
appearance is the same.
- Add a new pipeline RAN-PhySim-GraceHopper-5G that executes physical
simulators on gracehopper. Reporting is done in the same way as for
existing physical simulators (e.g., like in the RAN-PhySim-Cluster-5G
pipeline), but deployed in docker instead of helm.
-> some tests don't work reliably on ARM yet and are skipped
- the RAN-gNB-N300-Timing-Phytest-LDPC pipeline has been reworked to use
the same code for testing T2 offload, with ctest, and the same
reporting.
- the CUDA LDPC test XML has been removed, as these tests don't work
reliably.
- add a new macro add_timed_physim_test() that allows to define
thresholds to be checked, so that ctest will check for them. see the
documentation for more information
CI: Creation of F1 Handover pipeline
In this MR we are modifying/adding all the required files (.xml, .conf,
.yml) in order to create a pipeline on Jenkins that allows us to test
OTA F1 handover.