nr_fill_indication() fills CRC and RX requests, to be sent from L1 to
L2. Before this commit, nr_fill_indication() is called when
- we finally decoded LDPC (or not)
- low signal on PUSCH
This might happen at the same time, i.e., nr_fill_indication() might try
to fill both CRC and RX, in the same list, from different threads. This
can lead to this assertion:
Assertion (crc->rnti == rx->rnti) failed!
In handle_nr_ulsch() ../../../openair2/NR_PHY_INTERFACE/NR_IF_Module.c:190
mis-match between CRC RNTI e071 and RX RNTI 5e3b
e.g., e071 is low energy, and while 5e3b related message are filled in
one thread, e071 is being put into the message structure as well.
At least that is my understanding. I could not actually reproduce this
assertion; to be seen if it still happens.
Do not assert if the list of phy statistics is full; instead return
NULL.
In most places, this is handled appropriately (we do not store anything
if we can't). In nr_decode_pucch0(), the return value of get_phy_stats()
is used a little bit all over the function, and a constant
if (uci_stats)
uci_stats->variable++;
would look ugly, so make uci_stats point to the stack if we cannot store
in the phy_stats.
the uci_stats variable (pointing to per-UE statistics for UCI) is used
in function nr_decode_pucch0() to store information which is important
beyond statistics, e.g., uci_stats->pucch0_thres as a threshold (which
comes from somewhere else)
This commit refactors to use original or intermediate variables to not
mix uci_stats usage with actual processing.
Also, group uci_stats a bit more.
UBsan fails with errors without this commit. The commit changes:
- avoid two possible integer overflows in nr_dlsch_channel_level() and nr_dlsch_channel_level_median()
- nr_dlsch_channel_level_median() is simplified
- use MAX_ANT in avg to handle more than 4x4 config
- deleted: ../../../executables/rfsim.c
- removed unused command line options to set SINR and SNR
- removed unused functions to get SINR and SNR
- removed unused RFSIM struct members
PUSCH decoding is started multiple times in nr_ulsch_procedures() for
each ULSCH segment, and stopped once inside
phy_procedures_gNB_uespec_RX(). Not only is it not clear if that works
with the API, it also might measure more than just PUSCH decoding.
Remove the PUSCH decoding, it is misleading. Check L1 RX processing
instead.