Commit Graph
8 Commits
Author SHA1 Message Date
Robert Schmidt 8107939f08 Change OAI license to CSSL v1.0 (and others)
- all RAN code, CI code, configuration files, dockerfiles, in CSSL v1.0
- all deployment code (openshift, charts, ancillary files like shell
  scripts), in MIT
- documentation in CC-BY-4.0
- exceptions might apply and are listed in NOTICE
- there is a new LICENSES folder with all licenses
- CONTRIBUTIONS.md has been updated accordingly

For automated changes based on OAI PL v1.1:

    perl -i~ -0pe 's/\/\*.*Licensed to the OpenAirInterface.*openairinterface.org\n#?/\/*\n * SPDX-License-Identifier: LicenseRef-CSSL-1.0\n/s' **/*.{c,h,cpp}
    perl -i~ -0pe 's/\/\*.*Licensed to the OpenAirInterface.*openairinterface.org\n#?/\/*\n * SPDX-License-Identifier: LicenseRef-CSSL-1.0\n/s' **/*.ts
    perl -i~ -0pe 's/<!--.*Licensed to the OpenAirInterface.*openairinterface.org\n.*-->/<!-- SPDX-License-Identifier: LicenseRef-CSSL-1.0 -->/s' **/*.xml

The rest (cmake, files with missing license, cmake) manually.
2026-03-27 16:36:37 +01:00
Robert Schmidt c6bb50edb1 Add LogAnalysis in all XML files
I try to retain/match the previous log checks, without adding new
checks.
2026-02-26 14:17:28 +01:00
Robert Schmidt 50e133f791 Revert "CI: upgrade RAN-SA-Handover-CN5G F1 handover test to test Reestablishment on a different DU"
The CI test proved not as stable as expected (because the UE triggers A3
events which we don't want), so revert this functionality while we work
on a new pipeline.

This reverts commit bc62e8abca.
2026-01-30 15:55:33 +01:00
luis_pereira87 bc62e8abca CI: upgrade RAN-SA-Handover-CN5G F1 handover test to test Reestablishment on a different DU
- increase requirements for Event A3 trigger to avoid unwanted handovers
  and allow testing reestablishment on different DUs
- increase ping_packetloss_threshold from 5 to 30 because we are forcing
  a reestablishment, thus, packet loss will inevitably happen
- further adjustments to avoid A3 Events
2026-01-29 10:17:42 +01:00
Guido Casati 129b62e708 Telnet: improve fetch_du_by_ue_id to auto-detect connected UE
Issue: sometimes it happens that an ul failure occurs in the handover
pipeline, UE reconnects with different UE ID and fetch_du_by_ue_id fails.

- Modified fetch_du_by_ue_id in telnetsrv_ci.c to automatically find
  the connected UE when no UE ID is provided, similar to other
  telnet commands like rrc_gNB_trigger_f1_ho
- Updated test cases in container_sa_f1_ho_b210_quectel.xml to use
  the improved command without hardcoded UE ID parameter
- This makes the command more robust and easier to use in CI tests
2026-01-29 10:17:42 +01:00
Jaroslava Fiedlerova 12f4167f99 CI: Automatically enumerate test cases, remove hardcoded IDs
Update all XML files in ci-scripts folder, using Python script
attached in MR !3844.
https://gitlab.eurecom.fr/oai/openairinterface5g/-/merge_requests/3844#note_198132
2026-01-14 23:43:03 +01:00
Jaroslava Fiedlerova 32889870b3 CI: Adjust attenutation for HO setup 2025-10-30 13:37:15 +01:00
Guido Casati c3eaef704f Add monolithic N2 handover test pipeline with B210 and Quectel
- Add XML pipeline for N2 handover testing
- Add Docker compose for two monolithic gNBs
- Features:
  * Two monolithic gNBs (gNB1, gNB2) with proper CU+DU parameters
  * Gradual attenuation control using RC4DAT attenuator (5s duration)
  * N2 handover sequence: gNB1 → gNB2 → gNB1
  * Proper channel mapping: ch1-2 for gNB1, ch3-4 for gNB2
  * Telnet server configuration for CI commands
  * Handover-specific neighbor configuration
  * Clean test state management with attenuator reset
2025-10-22 14:48:34 +02:00