* added missing Transaction ID to te F1 Setup Failure message struct
* fill F1 Setup Failure transaction ID in RRC before calling the F1 Setup Failure function
- neighbour_config.conf file includes neighbour and measurement related parameters
Neighbour List:
- nr_cellid: the identity of existing cell who has neighbour
- neighbour_cell_configuration(list): includes the identity parameters
of the neighbour cell such:
- gNBID (incase of N2 Handover / to be identified from AMF)
- nr_cell_id (target gNB needs to consider)
- physical_cellId (needed for measurement reporting)
- absoluteFrequencySSB (needed for measurement reporting)
- subcarrierSpacing (needed for measurement reporting)
- plmn / tracking area code (incase of N2 Handover / needed for AMF
to identify / allow HO)
NR Measurement Configuration
- Periodical
- enable (default is 0, 1 enables the reporting)
- includeBeamMeasurements, maxNrOfRS_IndexesToReport (configurable
reporting parameters)
- A2
- enable (default is 0, 1 enables the reporting)
- threshold , timeToTrigger (configurable reporting parameters)
- A3
- cell_id (the nr_cellid of neighbour cell. So this A3 parameters
will be used for the neighbour
- [-1] means default. so it can be applied to any neighbour if
there is no specific config
- Neighbour specific A3 Threshold can be used or default can be
selected depending to the neighbour planning
- The neighbour-config.conf specifies, apply default A3 for
neighbours 3 and 4 | apply specific one for neighbour 2
- offset, hysteresis, timeToTrigger (configurable reporting parameters)
the neighbour_config.conf can be included in the gNB.conf file. Example
is given: gnb.sa.band78.106prb.rfsim.neighbour.conf
A sequence array container is used for neighbour cell configuration. RRC
structure has this container. A Measurement configuration structure is
defined. This structure has Periodical / A2 Event structures and also a
sequence container for A3 Event List.
These structures are filled during the initialization. While F1 Setup
Response is coming from DU to CU, the intra frequency / inter frequency
neighbour decision is given for the existing cell. Also new neighbours
could be added here if needed.
In the DU, read slice information from the DU config file. Handle
multiple slices within the F1 Setup Request structure representation,
and forward it via F1 to CU. The DU slice information is stored in the
setup request structure.
MeasTimingConfig may not come with F1 Setup Request: some DUs send it
with the DU configuration update. Handle this gracefully by checking for
MTC before using it.
Use the correct MIB data structure, MIB_t. This is required by 38.473,
and the LiteOn DU sends only that. So our CU needs to handle it, so
align the OAI DU as well.
38.473 section 8.2.3.1 says that upon F1 Setup Request, UE associated
signalling should be erased. In this commit, we trigger a release of all
UEs that were still connected to a DU when we received the SCTP
shutdown, i.e., when the DU disconnects.
RRC Version is a required IE. Hence, implement the encoder and decoder
for this message. At the DU and CU, read the RRC Version we use and fill
the corresponding field.
Co-authored-by: Robert Schmidt <robert.schmidt@openairinterface.org>
Multiple DUs host cells, whose cell ID cannot match (to identify them
uniquely). Hence, don't check for equality with CU, because otherwise,
we can never connect multiple DUs.
An assoc_id of 0 is used to mark UEs whose DU is "offline" (not
connected). In this patch, if a DU disconnects, we go through all UEs
and set their assoc_id to 0 if they belong to a UE that just went
offline.