In the DU, read slice information from the DU config file. Handle
multiple slices within the F1 Setup Request structure representation,
and forward it via F1 to CU. The DU slice information is stored in the
setup request structure.
Rewrite sctp_create_new_listener() to use getaddrinfo() to look up
IPv4/IPv6 addresses via a common interface. This allows to use e.g. DNS,
and enables the SCTP library to listen on IPv6 ports.
To support the above, the corresponding message is changed to not take
an IPv4 address on 4 bytes (and separate IPv6), but a single name that
will be resolved via getaddrinfo()
The previous init message used to allow multiple IPv4/IPv6 addresses;
since this is not used anywhere, remove the corresponding functionality.
Modify all uses of this ITTI message to copy te SCTP init bind addr into
ITTI message.
After the last commit, it is not possible to bind on separate interfaces
for F1-C and F1-U. In other words, it is for instance not possible to
have the F1-C on one subnet on one physical interface, and F1-U on
another subnet on another physical interface. This commit introduces a
second option MACRLCs.[0].local_n_address_f1u to allow to bind F1-U on
an alternative address; if it is not specified, the interface of F1-C is
reused.
The above only works for the DU; no corresponding option exists for the
CU. For the CU, use separate CU-CP and CU-UP.
Use it in the CI.
Introduce the structure nr_pdcp_integrity_data_t and adapt code to use it.
Note: in nr_pdcp_sdu_t we keep the 'count' variable (which is also present
in nr_pdcp_integrity_data_t). They represent the same value, but 'count'
in nr_pdcp_integrity_data_t is to be specifically used for integrity while
the other one has other uses, so it's better to keep it.
- PDCP reestablishment on CUCP (DRBs) triggering Bearer Context Modification procedures over E1
- Performing PDCP reestablishment for requested DRBs on CUUP
- Introduced function to notify re-establishment to CU-UP
- removed call to PDCP reestablishment for the DRBs on CUCP (it's done on CUUP)
cuup_notify_reestablishment:
- to fetch PDU session to setup in E1 following logic as in e1_send_bearer_updates
- fill bearer context modification request with stored F1-U tunnel information
during E1 reestablishment, otherwise it would initialized to 0 by default
- update GTP tunnel with the stored configuration after E1 reestablishment
- many structs and definitions are overlapping between the two different E1 procedures
- introduced naming specific to E1 Bearer Context Modification to improve readability
- grouped SDAP and PDCP configuration IEs for better reusability and readability
- introduced functions to set and get default PDCP config (DRBs and Bearer Contexts)
find_or_next_pdu_session:
- find_or_next_pdu_session refers to the E1 Bearer Context Modification Request
-- therefore it has to return pdu_session_to_mod_t* and takes in input e1ap_bearer_mod_req_t *
see !MR2545 for more context
- Phy configuration will be prepared by MAC
- Sidelink preconfiguration parameters passed from RRC->MAC
- Only 1 SSB TA allocation used
- psbch payload prepared by MAC after receiving the tx slss req
- CU-CP replying to the CU-UP with a Setup Failure message in case of unsuccessfull E1 Setup Request
- message is decoded by the CU-UP, and stops the process
RRC Version is a required IE. Hence, implement the encoder and decoder
for this message. At the DU and CU, read the RRC Version we use and fill
the corresponding field.
Co-authored-by: Robert Schmidt <robert.schmidt@openairinterface.org>
remove several unused files
remove mem_block_t that is never used in a different way than a simple heap buffer
move up IP address type and remove duplications of the same struct declaration
- Implement: Extend the F1 encoding and decoding with Qos
- Implement: E1 decoding for QoS
- Fix: Modify the UE_MODIFICATION_REQUEST_MSG towards DU to contain QoS info based on E1AP context response
- Fix: Modify the E1AP and F1AP message structures
- Fill the Qos configuration to send to MAC
3GPP has the concept of a gNB-CU-UP ID and a (separate) gNB ID (for gNB,
CU-CP). This commit introduces the gNB-CU-UP as a separate ID that has to be
set in the configuration file when running as a CU-UP. For the
CU/monolithic gNB, it is optional (but needs to be the same as the
gNB-ID if specified).
The CU-UP ID is necessary, as some entities, e.g., the e2 agent, need to
signal both IDs, e.g., to reconcile a CU-CP and (multiple) CU-UP(s)
belonging together.