* am test (SN field size 18):
|
|
* there was a bug when we receive a full PDU after receiving only the
|
|
* beginning of it; the data was copied at the end but from the start of the
|
|
* full PDU instead of the correct offset. This test captures this case.
|
|
* Gnb sends the start of a PDU then the full PDU. That is the SDU is
|
|
* [00 .. 09]. First gnb sends [00 .. 08] then it sends [00 .. 09].
|
|
*/
|
|
|
|
TIME, 1,
|
|
GNB_AM, 100000, 100000, 45, 35, 0, -1, -1, 8, 18,
|
|
UE_AM, 100000, 100000, 45, 35, 0, -1, -1, 8, 18,
|
|
GNB_PDU_SIZE, 12,
|
|
UE_PDU_SIZE, 20,
|
|
GNB_PDU, 12, 0x90, 0x00, 0x00, 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08,
|
|
TIME, 2,
|
|
GNB_PDU_SIZE, 20,
|
|
GNB_PDU, 13, 0xc0, 0x00, 0x00, 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x07, 0x08, 0x09,
|
|
TIME, -1
|