Files
openairinterface5g/ci-scripts/conf_files/neighbour-config-ho.conf
T
Cedric Roux b91a4c33bd fix configuration files
'timeToTrigger' has to be 'time_to_trigger'.

For A3 events, 'cell_id' has to be 'physCellId' and the value has to be
the one of the physical cell ID.
2026-01-05 16:25:28 +01:00

55 lines
1.0 KiB
Plaintext

neighbour_list = (
{
nr_cellid = 12345678;
neighbour_cell_configuration = (
{
gNB_ID = 0xe01;
nr_cellid = 11111111;
physical_cellId = 1;
absoluteFrequencySSB = 679104;
subcarrierSpacing = 1; #30 KHz
band = 77;
plmn = { mcc = 001; mnc = 03; mnc_length = 2};
tracking_area_code = 1;
}
)
},
{
nr_cellid = 11111111;
neighbour_cell_configuration = (
{
gNB_ID = 0xe00;
nr_cellid = 12345678;
physical_cellId = 0;
absoluteFrequencySSB = 679104;
subcarrierSpacing = 1; #30 KHz
band = 77;
plmn = { mcc = 001; mnc = 03; mnc_length = 2};
tracking_area_code = 1;
}
)
}
);
nr_measurement_configuration = {
Periodical = {
enable = 1;
includeBeamMeasurements = 1;
maxNrofRS_IndexesToReport = 4;
};
A2 = {
enable = 1;
threshold = 110;
time_to_trigger = 1;
};
A3 = ({
physCellId = -1; #Default
offset = 10;
hysteresis = 0;
time_to_trigger = 1
})
};