This document describes the SmallCellForum (SCF) (n)FAPI split in 5G, i.e., between the MAC/L2 and PHY/L1.

The interested reader is recommended to read a copy of the SCF 222.10 specification ("FAPI"). This includes information on what is P5, P7, and how FAPI works. The currently used version is SCF 222.10.02, with some messages upgraded to SCF 222.10.04 due to bugfixes in the spec. Further information about nFAPI can be found in SCF 225.2.0.

Quickstart

Compile OAI as normal. Start the CN and make sure that the VNF configuration matches the PLMN/IP addresses. Then, run the VNF

sudo NFAPI_TRACE_LEVEL=info ./nr-softmodem -O ../../../targets/PROJECTS/GENERIC-NR-5GC/CONF/gnb-vnf.sa.band78.106prb.nfapi.conf --nfapi VNF

Afterwards, start and connect the PNF

sudo NFAPI_TRACE_LEVEL=info ./nr-softmodem -O ../../../targets/PROJECTS/GENERIC-NR-5GC/CONF/gnb-pnf.band78.rfsim.conf --nfapi PNF --rfsim

Finally, you can start the UE (observe the radio configuration info in the VNF!)

sudo ./nr-uesoftmodem -r 106 --numerology 1 --band 78 -C 3619200000 -O ue.conf

You should not observe a difference between nFAPI split and monolithic.

Status

All FAPI message can be transferred between VNF and PNF. This is because OAI uses FAPI with its corresponding messages internally, whether a split is in use or not.

The nFAPI split mode supports any radio configuration that is also supported by the monolithic gNB, with the notable exceptions that only numerologies of 15kHz and 30kHz (mu=0 and mu=1, respectively) are supported.

The VNF requests to be notified about every slot by the PNF. No delay management is employed as of now; instead, the PNF sends a Slot.indication to the VNF in every slot (in divergence from the nFAPI spec).

Currently, downlink transmissions work the same in monolithic and nFAPI. In uplink, we observe an increased number of retransmissions, which limits the MCS and hence the achievable throughput (which is limited to 10-20Mbps). We are still debugging the root cause of this.

After stopping the PNF, you also have to restart the VNF.

When using RFsim, the system might run slower than in monolithic. This is because the PNF needs to slow down the execution time of a specific slot, because it has to send a Slot.indication to the VNF for scheduling.

Configuration

Both PNF and VNF are run through the nr-softmodem executable. The type of mode is switched through the --nfapi switch, with options MONOLITHIC (default if not provided), VNF, PNF.

If the type is VNF, you have to modify the MACRLCs.tr_s_preference (transport south preference) to nfapi. Further, configure these options:

  • MACRLCs.remote_s_address (remote south address): IP of the PNF
  • MACRLCs.local_s_address (local south address): IP of the VNF
  • MACRLCs.local_s_portc (local south port for control): VNF's P5 local port
  • MACRLCs.remote_s_portc (remote south port for data): PNF's P5 remote port
  • MACRLCs.local_s_portd (local south port for control): VNF's P5 local port
  • MACRLCs.remote_s_portd (remote south port for data): PNF's P7 remote port

Note that any L1-specific section (L1s, RUs, RFsimulator-specific/IF7.2-specific configuration or other radios, if necessary) will be ignored and can be deleted.

If the type is PNF, you have to modify modify the L1s.tr_n_preference (transport north preference) to nfapi. Further, configure these options:

  • L1s.remote_n_address (remote north address): IP of the VNF
  • L1s.local_n_address (local north address): IP of the PNF
  • L1s.local_n_portc (local north port for control): PNF's P5 local port
  • L1s.remote_n_portc (remote north port for control): VNF's P5 remote port
  • L1s.local_n_portd (local north port for data): PNF's P7 local port
  • L1s.remote_n_portd (remote north port for data): VNF's P7 remote port

Note that this file should contain additional, L1-specific sections (L1s, RUs RFsimulator-specific/IF7.2-specific configuration or other radios, if necessary).

To split an existing config file monolithic.conf for nFAPI operation, you can proceed as follows:

  • copy monolithic.conf, which will be your VNF file (vnf.conf)
  • in vnf.conf
    • modify MACRLCs section to configure south-bound nFAPI transport
    • delete L1s, RUs, and radio-specific sections.
    • in gNBs section, increase the ra_ResponseWindow by one to extend the RA window: this is necessary because the PNF triggers the scheduler in the VNF in advance, which might make the RA window more likely to run out
  • copy monolithic.conf, which will be your PNF file (pnf.conf)
  • in pnf.conf
    • modify L1s section to configure north-bound nFAPI transport (make sure it matches the MACRLCs section for vnf.conf
    • delete all the gNBs, MACRLCs, security sections (they are not needed)
  • if you have root-level options in monolithic.conf, such as usrp-tx-thread-config or tune-offset, make sure to to add them to pnf.conf, or provide them on the command line for the PNF.
  • to run, proceed as described in the quick start above.

Note: all L1-specific options have to be passed to the PNF, and remaining options to the VNF.

nFAPI logging system

nFAPI has its own logging system, independent of OAI's. It can be activated by setting the NFAPI_TRACE_LEVEL environment variable to an appropriate value; see the environment variables documentation for more info.

To see the (any) periodical output at the PNF, define NFAPI_TRACE_LEVEL=info. This output shows:

41056.739654 [I] 3556767424: pnf_p7_slot_ind: [P7:1] msgs ontime 489 thr DL 0.06 UL 0.01 msg late 0 (vtime)

The first numbers are timestamps. pnf_p7_slot_ind is the name of the functions that prints the output. [P7:1] refers to the fact that these are information on P7, of PHY ID 1. Finally, msgs ontime 489 means that in the last window (since the last print), 489 messages arrived at the PNF in total. The combined throughput of TX_data.requests (DL traffic) was 0.06 Mbps; note that this includes SIB1 and other periodical data channels. In UL, 0.01 Mbps have been sent through RX_data.indication. msg late 0 means that 0 packets have been late. This number is an aggregate over the total runtime, unlike the other messages. Finally, (vtime) is a reminder that the calculations are done over virtual time, i.e., frames/slots as executed by the 5G Systems. For instance, these numbers might be slightly higher or slower in RFsim than in wall-clock time, depending if the system advances faster or slower than wall-clock time.