LocationandBandwidth adjusted according to the location of SSB and Controlresourceset 0
For example for 106RBs configuration files -
- AbsoluteFrequencySSB = 641032 = RB43 (1032/24) - points to Subcarrier 0 of RB10 of SSB block
- Hence SSB is located from RB33-RB53
- Coresetzero sent in MIB is 0 which means offset 0, RBsize 24 from Start of SSB according to table 13.4 in Spec 38.213
- InitialBWP should start from RB 33 (offset is 0 from SSB) and should be a size of minimum 24 RBs.
- SLIV = 275 * (24-1) + 33 = 6358
Controlresourceset value wrongly configured to 12 , changed to 0 as sent in MIB.