set ntn-UlSyncValidityDuration-r17 to 5 seconds for LEO scenario
Now that we reliably receive SIB19, we can set the ntn-UlSyncValidityDuration-r17 to a sane value and thus make sure that the UE always has up-to-date SIB19 information.
This commit is contained in:
@@ -150,6 +150,8 @@ gNBs =
|
||||
|
||||
#ext2
|
||||
#ntn_Config_r17
|
||||
# This can be of values {s5, s10, s15, s20, s25, s30, s35, s40, s45, s50, s55, s60, s120, s180, s240, s900}
|
||||
ntn-UlSyncValidityDuration-r17 = 5;
|
||||
cellSpecificKoffset_r17 = 40;
|
||||
ta-Common-r17 = 4627000; # 18.84 ms
|
||||
ta-CommonDrift-r17 = -230000; # -46 µs/s
|
||||
|
||||