Merge remote-tracking branch 'origin/fix-mcs-tbl' into integration_2025_w48 (!3774)

Use UL functions for Qm/R determination

During refactoring, the wrong functions and correspondingly tables have
been used to calculate UL TB size. Fix through correct functions.
This should fix these error messages:

3624774.778195 [MAC]    E (nr_get_Qm_dl:2034)             Invalid MCS table index 3 (expected in range [0,2])
3624774.778207 [MAC]    E (nr_get_code_rate_dl:2066)      Invalid MCS table index 3 (expected in range [0,2])
3624774.778211 [NR_MAC] E (nr_compute_tbs:63)             Error in compute TBS with a NULL input, returning NULL TBS

Fixes: 9449f777 ("Remove TBS table and recompute on demand")
This commit is contained in:
Jaroslava Fiedlerova
2025-11-24 22:26:42 +01:00
@@ -2081,8 +2081,8 @@ static int pf_ul(gNB_MAC_INST *nrmac,
/* Create UE_sched for UEs eligibale for new data transmission*/
/* Calculate coefficient*/
const uint8_t Qm = nr_get_Qm_dl(selected_mcs, current_BWP->mcs_table);
const uint16_t R = nr_get_code_rate_dl(selected_mcs, current_BWP->mcs_table);
const uint8_t Qm = nr_get_Qm_ul(selected_mcs, current_BWP->mcs_table);
const uint16_t R = nr_get_code_rate_ul(selected_mcs, current_BWP->mcs_table);
const uint32_t tbs = nr_compute_tbs(Qm,
R,
1, /* rbSize */