batuhan duyulerandGuido Casati 75c7220345 Refactored code to populate DRBs to be setup list in nr_initiate_handover
Co-authored-by: Guido Casati <guido.casati@firecell.io>
2025-06-09 20:12:12 +02:00
batuhan duyuler edeb7b8f61 handling 1st digit of mnc in SIB1
During preparation of SIB1, first digit of MNC was not taking into account.
This leads to XRES*, RES* mismatch during Authentication Procedure between 5GCore and UE because of derived serving network names.
2024-10-29 16:43:26 +01:00
batuhan duyuler c51b2a64fb Prepare Measurement Configuration according to neighbour measurement configuration
Neighbor configuration can be given by gNB.conf

get_MeasConfig function is extended as it will prepare A2 / A3 Report
Configs. Single Meas Obj is used for all.

rrc_gNB_process_MeasurementReport function is extended to process A2 /
A3 measurement events.  helper functions are written to fetch neighbour
cell informations from sequence containers.
(get_neighbour_cell_information, get_neighbour_config)
2024-06-04 07:54:00 +02:00
batuhan duyuler cec6b8925a Preparation of Neighbour Configuration & Measurement Configuration | Parsing the configuration
- neighbour_config.conf file includes neighbour and measurement related parameters
Neighbour List:
 - nr_cellid: the identity of existing cell who has neighbour
 - neighbour_cell_configuration(list): includes the identity parameters
   of the neighbour cell such:
    - gNBID (incase of N2 Handover / to be identified from AMF)
    - nr_cell_id (target gNB needs to consider)
    - physical_cellId (needed for measurement reporting)
    - absoluteFrequencySSB (needed for measurement reporting)
    - subcarrierSpacing (needed for measurement reporting)
    - plmn / tracking area code (incase of N2 Handover / needed for AMF
      to identify / allow HO)

NR Measurement Configuration
 - Periodical
    - enable (default is 0, 1 enables the reporting)
    - includeBeamMeasurements, maxNrOfRS_IndexesToReport (configurable
      reporting parameters)
 - A2
    - enable (default is 0, 1 enables the reporting)
    - threshold , timeToTrigger (configurable reporting parameters)
 - A3
    - cell_id (the nr_cellid of neighbour cell. So this A3 parameters
      will be used for the neighbour
        - [-1] means default. so it can be applied to any neighbour if
          there is no specific config
        - Neighbour specific A3 Threshold can be used or default can be
          selected depending to the neighbour planning
        - The neighbour-config.conf specifies, apply default A3 for
          neighbours 3 and 4 | apply specific one for neighbour 2

    - offset, hysteresis, timeToTrigger (configurable reporting parameters)

the neighbour_config.conf can be included in the gNB.conf file. Example
is given: gnb.sa.band78.106prb.rfsim.neighbour.conf

A sequence array container is used for neighbour cell configuration. RRC
structure has this container.  A Measurement configuration structure is
defined. This structure has Periodical / A2 Event structures and also a
sequence container for A3 Event List.

These structures are filled during the initialization. While F1 Setup
Response is coming from DU to CU, the intra frequency / inter frequency
neighbour decision is given for the existing cell. Also new neighbours
could be added here if needed.
2024-06-04 07:54:00 +02:00
batuhan duyuler e5afdcdd43 Move cell-value lookup functions (SSB ARFCN, ...) to rrc_gNB_du.c
The functions are needed in a later commit in both rrc_gNB_du.c and
rrc_gNB.c, so move to the rrc_gNB_du.c file concerned with DUs (cells).
2024-06-04 07:43:54 +02:00