the standard in 213 8.4 says: "In response to the PDSCH reception with the UE contention resolution identity, the UE transmits HARQ-ACK information in a PUCCH."
Long PRACH extends beyond a slot. Changes necessary to mark future slots
that may contain prach in ru, phy and mac functions.
In RU, the PRACH IDFT is done only after receiving last slot and marks
for L1 to start processing. The L1 processes at the last prach slot and
reports to MAC with the first slot index.
In MAC scheduler, the VRB for future slots are also marked as used.
PRACH scheduler is called in advance one frame minus num prach slots.
function returns mu of UL BWP if msg1-SubcarrierSpacing absent instead
of asserting. The mu retured by this function is used to compute the
slot number of PRACH. In case of long format, the slot number is as per
UL mu.
The aggregation level search order for PDCCH candidates is modified:
- the search starts from desired_agg_level_index, which is a value from 0 to 4
proportial to pdcch_cl_adjust.
- pdcch_cl_adjust is a value between 0 and 1 that indicates PDCCH channel quality
by averaging HARQ DTX rate. A value of 0 means perfect channel, a value o 1 means
impaired channel.
Reset E1 UE contexts after E1 Setup Response
38.463 sec. 8.2.3 says
> This procedure also re-initialises the E1AP UE-related contexts (if
> any) and erases all related signalling connections in the two nodes
> like a Reset procedure would do.
Hence, delete all contexts after reception of E1 Setup Response. This
minimizes a risk of receiving an E1 bearer setup req for an existing UE,
which currently leads to an assert [we trust the CU-CP does not send the
same UE ID twice, as we only "mirror" the existing UE ID]. After this
MR, this is what happens if these entities fail:
- CU-CP fails: all context lost implicitly, upon reconnection, both DU
and CU-UP reset all contexts (like "start from zero")
- DU fails: CU-CP triggers NGAP UE context release request immediately
(radio connection with UE lost), all UE contexts attached to this DU
cleared (like "start from zero" for affected DU)
- CU-UP fails: initially, nothing (UE has no user plane); upon
reconnection of CU-UP, CU-CP triggers NGAP UE context release request
(cause radio connection with UE lost) and sends F1 Reset to DU, all UE
contexts associated to this DU cleared (like "start from zero")
for the last case, a possible improvement could be to use the F1 Reset
message to only clear affected UE conetxts. I chose not to do this,
because this MR is very big now already, and possible "victim" UEs
that were not at that CU-UP will reconnect as well
Downgrade gNB power limit LOG from "warning" to "debug"
Downgrade the UE power limited LOG from LOG_W to LOG_D. This is to avoid
flooding stdout when UE in low coverage enters power limited state for a
longer period of time. The same information can be inferred from the
periodic UE print which also contains PH value (negative PH values
indicate that the UE is power limited)
Also, correct some typos in PH calculation.
Closes#885
Changes to support multiple TDD patterns
- Updated the configuration changes for 2 Patterns
- Update the TDD table configuration for NFAPI
- Added the tdd bitmap for the period
- Adapted the bitmap for UL/DL for the multi TDD pattern
- Updated the RACH procedure for multi TDD pattern
- Updated DL and UL scheduler for multi TDD pattern
* Remove the ulsch_slot_bitmap and dlsch_slot_bitmap from nrmac
* Adopt the new is_dl_slot/is_ul_slot functions in the stack
to replace is_xlsch_in_slot: these functions are getting
the DL and UL slots as they are set in the TDD configuration
stored in tdd_slot_bitmap (frame_structure_t)
* Keep is_xlsch_in_slot in openair2/LAYER2/NR_MAC_gNB/gNB_scheduler_phytest.c:
this is necessary because the phy-test pre-processors are using the bitmaps
dlsch_slot_bitmap and ulsch_slot_bitmap to check which DL/UL slots to use
for transmission among those set in the TDD configuration
Co-authored-by: Guido Casati <guido.casati@firecell.io>
Downgrade the UE power limited LOG from LOG_W to LOG_D. This is to avoid flooding
stdout when UE in low coverage enters power limited state for a longer period of
time. The same information can be inferred from the periodic UE print which also
contains PH value (negative PH values indicate that the UE is power limited)
* is_ul_slot: returns `true` for UL or mixed slots
* is_dl_slot: returns `true` for DL or mixed slots
* is_mixed_slot: returns `true` for mixed slots
These functions use the TDD slot bitmap for slot type checks
Co-authored-by: Guido Casati <guido.casati@firecell.io>
* the function is returning the index of the first full UL slot in tdd_slot_bitmap
or the first UL slot (including mixed) if the "mixed" flag is provided
* the get_ul_slot_offset function calculates the offset of the nth uplink (UL) slot for a given UE index within a TDD period
* this function uses the frame structure bitmap to determine the UL slot positions