The pipeline is using the already existing conf files
for the source/target gNB CUs/DUs.
For the sake of simplicity, neighbour-config.conf has
been rewritten and simplified in this commit, then
adopted in this pipeline. The file was not used before.
CI: Creation of F1 Handover pipeline
In this MR we are modifying/adding all the required files (.xml, .conf,
.yml) in order to create a pipeline on Jenkins that allows us to test
OTA F1 handover.
Reworking BWP configuration
This MR reworks the configuration via fail of additional BWPs. Moreover, it
allows for a single BWP to be configured for a given UE at a given time (BWP
switch possible only via reconfiguration). It also reworks PTRS configuration
for consistency with the BWP one.
Fixes and updates for UL scheduling, notably DSUUU
Fix a number of problems that stem from !3521, notably regarding Msg3
scheduling, retransmissions in "UL-heavy" TDD scenarios, and BSR
handling. Modify a CI test to run a UL-heavy TDD scenario, and add
documentation for UL-heavy TDD scenarios.
The parameter is either set to 10 (the default, so not necessary), or to
0 forcing the gNB to schedule the UE all the time, which is only
necessary in specific scenario, and here simply wrong.
Refactor ULSCH scheduler towards more TDD pattern flexibility
Refactors ULSCH scheduler, notably to support "UL-heavy" TDD patterns,
e.g., DSUUU. Also allows to run TDD pattern2 with UL slots, which was a
limitation in the previous code.
Increase the number of aggregration level candidates. Since we have many
UEs with concurrent traffic in that pipeline, we should ensure that we
can allocate many DCIs to not waste resources (e.g., not all RBs used
because could not find DCIs for specific UEs).
Make Amarisoft UE sim a RedCap UE
Change Amarisoft UE configuration and gNB of the AW2S pipeline to
be/handle RedCap UEs.
The UE should only connect if the gNB handles RedCap UEs. In the logs,
we should see
[MAC] UE with RNTI 3725 is RedCap
which we check for the first two UEs (one normal UE/absence of this
message, one RedCap UE/presence of this message).
Add a CU-UP load tester and improve GTP performance
This adds a simple tester program for the CU-UP. It sets up a number of
UEs/bearers in the CU-UP via the E1 interface, then streams data in
downlink/uplink (as seen by the CU-UP). More information is available in
tests/nr-cuup/README.md.
Includes some fixes to properly verify that SCTP is installed, and use
"the right cmake way" to use it in cmake code (see commit for details).
Remove these F1-C port numbers. The configuration is not actually
applied, and the default F1-C port number 38472 (see F1AP_PORT_NUMBER)
is hardcoded in the F1 module.
For the moment, I leave the configuration option, in case we want to
allow to configure the port numbers later).
Now that we reliably receive SIB19, we can set the ntn-UlSyncValidityDuration-r17 to a sane value
and thus make sure that the UE always has up-to-date SIB19 information.
Since the parent commit, the ra_ResponseWindow will be chosen
automatically. Correspondingly, remove most ra_ResponseWindow options
from configuration files in the repository.
One problem in some mu=1 configs is that the ra_ResponseWindow=4 (10
slots), which might be overly restrictive if the L1 slot ahead is
somewhat close to 10 (e.g., 6), in which case we might not be always
able to allocate Msg2 in time.
A notable exception here is gnb-vnf.sa.band66.u0.25prb.nfapi.conf, in
which we still provide it (1) since it uses a non-standard configuration
of a ra_ResponseWindow longer than 10ms (see also issue #916 for more
information) and (2) as an example.
Fix Dedicated BWPs
- Improve SearchSpace selection
- Improve CORESET selection
- Fix fill 'initialDownlinkBWP->pdsch_Config' when there are
DedicatedBWPs
* This fixes the reported 'RSRP = 0' issue when the UE is in the
InitialBWP and we have DedicatedBWPs configured
- Add a 'common' type SearchSpace in the NR_BWP_DownlinkDedicated IE for
DedicatedBWPs
- Fix hardcoded 'controlResourceSetId' by making it dynamic
- Remove 'searchspaceid' from 'verify_agg_levels' function because it
was used only for LOG
- CI: Add DedicatedBWP to '40 MHz TDD F1+E1 SA' in
'RAN-SA-B200-Module-SABOX-Container'
Following frequency change in the pipeline, we observed degraded UL channel
conditions resulting in low UL throughput. Increasing attenuation on the gNB
side was found to mitigate this issue by improving UL channel quality
and reducing UL noise power.
Increase tested UL and DL bitrates in OAIUE pipeline.
bugfix: read msg_type only after deciphering
There was a problem with accessing msg_type from the input buffer before
deciphering, giving obviously wrong value.
CI team: we should add a test in the CI with NAS ciphering + integrity
(connection to the core) set to not null (I suggest nea2/nia2). With
openair's core, this is done by setting this in the amf config file
(nia1 and nea2 at the top of the list):
supported_integrity_algorithms:
- "NIA2"
- "NIA1"
- "NIA0"
supported_encryption_algorithms:
- "NEA2"
- "NEA1"
- "NEA0"
And also put full security in the AS. This is done with this in the gnb
config file:
security = {
ciphering_algorithms = ( "nea2", "nea0" );
integrity_algorithms = ( "nia2", "nia1", "nia0" );
drb_ciphering = "yes";
drb_integrity = "yes"
};
Ideally we should test this with both openair UE and cots UE. But as a
strict minimum do for openair UE (this is where the bug was).
No need to do much traffic, a few ping is enough. But if you want to
check throughput with full security, why not.
Enabling usage of ulsyncvalidityDuration timer in SIB19
ntn-UlSyncValidityDuration in SIB19 from Spec 38.331 v17.12 A validity
duration configured by the network for assistance information which
indicates the maximum time duration (from epochTime) during which the UE
can apply assistance information without having acquired new assistance
information. The unit of ntn-UlSyncValidityDuration is second. Value s5
corresponds to 5 s, value s10 indicate 10 s and so on.
ntn-UlSyncValidityDuration-r17 ENUMERATED{ s5, s10, s15, s20, s25, s30, s35,s40, s45, s50, s55, s60, s120, s180, s240, s900}
Implementation of epochtime is under discussion.
It can be configured in configuration file according to the above
enumeration. For GEO - 240s, MEO - 20s, LEO-5s can be used.
Following a power cycle of the CI machines in the NSA-B200 setup, the gNB
machine encountered a networking issue. Although packets were observed leaving
and returning to the host of gNB, they failed to reach the container.
Debugging steps taken:
- upgraded the gNB machine
- reinstalled Docker
- reviewed and verified IP rules and routing settings
Setting the container to use host network mode resolved the issue.
Improve radio for Metanoia RU (and likely others)
We introduced a regression that lowered the achievable DL throughput
with at least the Metanoia RU (i.e., in the configuration and the UE
that we use). git bisect showed up one commit, which does not seem
necessary. We just revert this commit, as it improves the throughput and
does not seem to have a negative impact on performance.
Further, increase RLC buffers a bit. Limit 7.2 pipeline number of layers
to 2.
With PMI reporting working (see HEAD^^), it seems that four layers put
two much processing strain on the machine (cacofonix), which asserts
immediately. In tests, it was found that the same test throughput
(600Mbps) can be achieved with two layers, while not crashing the
machine.
CI: Replacing Devkit server with a Grace Hopper in Aerial pipeline
Switch servers on the Aerial pipeline from Gigabyte (AMD) to Grace
Hopper (ARM), and make the necessary changes:
- Update XML, YAML, and gnb.conf
- Change the argument passed to the L1 in aerial_l1_entrypoint.sh to be
compatible with the GH
- Update the Aerial setup in TESTBench.md and Aerial_FAPI_Split_Tutorial.md docs
- Decrease the tested throughput due to an issue with the RU. Will open
another MR to increase it once the problem is fixed.