Add Ethernet PDU session support and make PDU session request configurable
This MR adds support for Ethernet PDU sessions, and makes PDU sessions
configurable: per-PDU session ID, type (IPv4/IPv4v6/IPv6/Ethernet [1]),
DNN, NSSAI.
Concretely, it adds a new configuration file section pdu_sessions below
uicc0 that looks like this if everything is specified (default values
are shown):
uicc0:
[...]
pdu_sessions:
- id: 1
type: "IPv4"
nssai_sst: 1
nssai_sd: 0xffffff
dnn: "oai"
It is possible to list multiple PDU sessions (add new line - id: 2 to
request a second PDU session). It is backwards-compatible to the current
PDU session configuration (uicc0.dnn/nssai_sst/etc), the idea being that
either legacy or new configuration could be used, but (1) if
pdu_sessions exist, it will overwrite the legacy configuration, and (2)
multiple PDU sessions, and type, can only be configured using the new
config. The old parameters --extra-pdu-id and --default-pdu-id are not
accepted anymore. Documentation has been added to the UE tutorial.
It is possible to test an Ethernet PDU session [1]. It is possible to
test the PDU session inside the UE by verifying it has an TAP interface
oaitap_ue1, and ARPing the data network (arping has been added to
oai-nr-ue container for that purpose):
ip addr add 192.168.72.140/26 dev oaitap_ue1 # same subnet as data network!
ip link set dev oaitap_ue1 up
arping -c 20 -I oaitap_ue1 192.168.72.135 # will send ARP request in Ethernet frame to get IP address of data network
[1] See description MR !3769 for more information. On the UE side, only
the type has to be changed to "Ethernet".
NR UE: add support for multiple RF frontends
This MR adds basic support for multiple RF-frontends at the UE.
There are multiple reasons why we might want this:
1. There might be different antennas needed for different bands (e.g. NTN or
TN antennas). These antennas might be connected to different RF-frontends.
In case of Handover, the UE needs to dynamically switch between these
RF-frontends.
2. Each rf-simulator connection carries baseband I/Q samples. To be able to
perform a handover between two cells at different frequencies, there must
be two rf-simulator connections, as the baseband channels should not
interfere and thus cannot simply be added.
3. When we want to support multiple UE simulation within one instance of
nr-uesoftmodem, and allow multiple cells and probably even handover between
these cells, we need either:
1. dedicated RF-frontends for each simulated UE, or
2. dedicated RF-frontends for each connected cell and dynamically assign
simulated UEs accordingly.
This MR implements what is needed for 1., 2. and 3.1.
Standardize Documentation Formatting and Navigation for MkDocs
This merge request improves and organizes the documentation to align with MkDocs
requirements. The following guidelines have been applied:
Guidelines Followed
Fix Broken Links and Paths
- Updated all links with proper paths to ensure correct rendering in MkDocs.
Correct Headings
- Removed multiple H1 headings (#).
- Subheadings use H2–H6 (## to ######) for consistent structure.
Proper URL Formatting
- All URLs now follow standard Markdown syntax,
e.g., [Example](https://www.example.com).
Proper Syntax
- Tables, lists, and code blocks use standard Markdown formatting to ensure
correct rendering.
Remove HTML Formatting
- Removed unnecessary inline HTML styling from documents, retaining only the
content.
Notes and Warnings
- Converted notes and warnings into blockquote syntax (>).
This ensures the documentation is properly structured, consistent, and
MkDocs-friendly.
- Include functions/file_names in backticks for readability
- Include the images directly inside the document (rather than plain image file name)
- Give relevant spacing if required
- Remove multiple single top-level (# H1) headings per file
- Use (# H2 and ###### H6) sub-headings for consistency
- Remove any trailing # in the headings
- This ensures proper table of contents rendering in MkDocs.
- Also removed RUN_NR_multiple_BWPs.md as it is moved to MAC usage
- bold current status for clarity and add spacing for better readability
- Wrap processes in the test setup block inside code blocks as they were rendered as GitLab issues
- Remove extra spacing in the test setup block
- Give a line in between bullet points to reflect bullet points correctly
- Split long statement into bullet points for readability
- Format the document for proper rendering
- Fix table formatting
- Use standard TOC syntax in 5GNAS
- The parser was incorrectly interpreting `</` as the start of an HTML closing tag, leading to a crash in mkdocs
- Replace with HTML entity to ensure it is treated as a plain text.
NR UE: add neighboring cell measurements and measurement report of event A3
This is a rework of MR !2385 (closed), the goal is to add neighboring cell
measurements and measurement report of event A3 for NR UE.
This MR was tested with:
- 3rd-party gNB
- 2 OAI-gNB-DUs
The neighboring cell measurements and measurement report of event A3 for OAI-UE
are working as expected.
When doing analogue beamforming, the beam ID for a pre-defined beam
table is passed directly to RU and there is no need to store the beam
table in PHY.
Update documenation for handover
Update documentation for handover to include the changes that were made after
upgrading the CI handover setup (attenuator, USRPs synchronization)
NR UE: calculate TA based on SIB19 information in NTN mode, if autonomous TA is not enabled
To achieve the goal, the hyper frame number (HFN) is introduced at the NR UE
PHY, MAC and RRC layers.
Besides this, we also implemented an orbit propagation to improve the accuracy
of N_UE_TA_adj, and a fix to keep the N_TA from RAR and MAC CE.
Fixes#981
Fix FAPI WLS timing, UL counter, doc
- Fix FAPI WLS timing
- Fix periodical PNF UL throughput logs
- Update documentation to better explain how to run WLS with radio (USRP
B210)
Fixes for BWP switching
This MR fixes some issues when performing BWP switching via
reconfiguration. It also adds a CI test for BWP switching. # Please
enter a commit message to explain why this merge is necessary,