improvements in formatting and LOGs in DMRS common functions at MAC
DMRS LOGs at MAC were misleading. This MR tried to improve them (and also
adds some formatting fix).
Integration: `2025.w43`
* !3605 Support beam index in OAI 7.2 Fronthaul Interface
* !3709 Fixes for T-Tracer to work with NR-UE
* !3712 Restore UE Capability IE after RRCReestablishment
* !3716 Remove unused ULSCH measurements at gNB
* !3603 UE symbol based PDCCH receiver
* !3708 Add monolithic N2 handover test pipeline with B210 and Quectel
* !3719 Remove Benetel-specific radio drivers
* !3710 [CI] Update the Push to DockerHub Stage
* !3711 CI: Multiple adjustments
* !3717 Initialize NCC=0 on NGAP Initial Context Setup (3GPP TS 33.501 §6.9.2.1.1)
* !3720 fix direct bugs of not used RU_RX_SLOT_DEPTH defined constant
* !3714 Improve handling of selection of RSRP/SINR report via configuration file
* !3519 Refactor SDAP adaptation work for QoS
* !3698 Other CSI measurement fixes
* !3699 Updates for Feature Set
Closes#1008
See merge request oai/openairinterface5g!3713
Other CSI measurement fixes
Errors fixed in this MR:
- UE currently sends empty CSI measurement report resulting in invalid
cqi_idx 0, default to MCS 9 at gNB because mismanagement of new L1
measurement structure at MAC UE
- nrofReportedRS not updated after UE capability reception at gNB
- multiple RSRP reports multiplexed / de-multiplexed in wrong order
Refactor SDAP adaptation work for QoS
This MR is an adaptation of the code introduced in !2703.
The goal is a cleanup and functional refactor of the SDAP/PDCP
integration, that is:
- centralize SDAP configuration logic
- simplify entity creation
- improve robustness of role-based SDAP handling
- prepare the codebase for clean support of DRB reconfiguration and
teardown flows
More concretely:
1. New sdap_config_t and get_sdap_Config()
- Introduced an internal struct sdap_config_t to abstract SDAP config
input
- Centralized SDAP config parsing into new get_sdap_Config() function
that translates ASN.1 NR_SDAP_Config into this internal
representation. This is called during RRC triggered
(re)configuration procedures.
- Enable mapping of number of QoS flows > 1
2. Unified role handling with bitmasks
- Added a bitmask-based entity_role field to track SDAP directions:
SDAP_UL_RX, SDAP_UL_TX, SDAP_DL_RX, SDAP_DL_TX: header presence was
determined by simple direction (UE vs gNB) and individual
is_sdap_rx/tx() checks, however nr_sdap_rx_entity behaves
differently depending on the direction of the RX entity (DL/UL),
therefore this change can help enable a more accurate SDAP header
handling across directions and node types.
- Replaces old helpers is_sdap_rx() / is_sdap_tx() with internal
checks against the role bitfield
- QFI-to-DRB mapping is now annotated with direction for both data and
control PDUs
3. Simplified DRB and SDAP setup
- add_drb() in PDCP API now delegates SDAP config processing cleanly
- new_nr_sdap_entity() is used consistently to register a fresh SDAP
context for the UE and PDU session.
- Also, re-use and reconfigure existing SDAP entity if already
exists.
- logging has been added to trace mapped QFIs from RRC and resulting
table entries
4. Improved QFI-to-DRB management
- Refactored nr_sdap_qfi2drb_map_update() to register QFIs based on
parsed config
- Ensures control PDUs are correctly routed even after reconfiguration
- Extended nr_sdap_ue_qfi2drb_config: perform UL QoS flow to DRB
mapping configuration for a SDAP entity has already been established
according to TS 37.324, 5.3 QoS flow to DRB Mapping, 5.3.1
Configuration Procedures. Handle both UL QoS Flows mapping rules to
add and to remove. QFIs will now be properly unmapped if specified
via mappedQoS_FlowsToRelease, this might prevent stale QFI mappings
from being used incorrectly.
- nr_sdap_qfi2drb() and sdap_map_ctrl_pdu() now strictly fallback to
default_drb only if a QFI mapping is missing. Missing default DRB
now triggers LOG_E() (previously silent or misrouted to DRB 0).
5. Other cleanup
- Remove dependencies from legacy rb_id_t
Improve handling of selection of RSRP/SINR report via configuration file
In current develop, the selection of SSB or CRI RSRP depends on the
do_CSIRS flag being activated. That's not wanted. CRI report for now it
is never handled, while we need SSB RSRP report for beam switching
regardless of CSI-RS configuration.
This commit refactors the SDAP entity QoS flow to DRB mapping functionality
to improve code organization and enhance maintainability.
Key changes:
- Split nr_sdap_qfi2drb_map_update into focused functions:
* nr_sdap_add_qos_flows_to_drb: handles QFI addition to DRB
* nr_sdap_rm_qos_flows_from_drb: handles QFI removal from DRB
* nr_sdap_ue_control_pdu_config: handles UE control PDU generation
- Consolidate add/modify logic into reusable nr_sdap_addmod_entity function
- Remove entity existence checking and updating from new_nr_sdap_entity:
this function should only add SDAP entities
- Improve function separation of concerns: do SDAP entity add or update
separately and improve modularity by splitting operations in self
contained functions
- At SDAP creation, do only add of QFI to DRB mapping
- rename new_nr_sdap_entity to nr_sdap_add_entity for function naming consinstency
- Remove rb_id parameter from nr_sdap_tx_entity() function signature
- Update tx_entity function pointer
- Remove rb_id parameter from sdap_data_req() function signature
- Remove unused rb_id variable from sdap_tun_read_thread
The rb_id parameter was redundant since SDAP determines DRB ID
from QFI mapping via entity->qfi2drb_map(entity, qfi). This
simplifies the interface.
Each QFI should always be mapped to a DRB. If that is not the case, we
have an undefined behavior. This should not occur. This commit prints
an error in tx_entity and returns.
The TX/RX entity should have different behavior according to
5.2.1, 5.2.2, 3GPP TS 37.324, depending on whether it is UL and DL.
The gNB can play a role both as UL RX entity and DL TX entity, while
the UE can play a role both as UL TX entity and DL RX entity.
The goal of this commit is to extend the information stored in the
SDAP entity as the current code is just marking the entity as TX/RX.
The commit introduces a bitmap to store the role of the
entity, which can be DL RX, DL TX, UL RX and UL TX. Based on this
the TX SDAP entity knows whether a DL/UL PDU should be build, and
the RX SDAP entity knows whether a DL/UL PDU should be processed.
See also Figure 4.2.2-1.
SDAP headers are present only if enable_sdap option is used.
nr_sdap_qfi2drb_map_update function pointer should
process QFIs to add and release from the entity mapping, therefore
a new function pointer for QFIs to add was introduced and
the function pointer to release the QFIs was called in the same function.
Now the nr_sdap_qfi2drb_map_update is:
(1) looping through the QFIs to add/update and store in the qfi2drb_table
(2) looping through the QFIs to release and delete from qfi2drb_table
Also:
* Update the function signature to use sdap_config_t and nr_sdap_entity_t
* log error when the update fails
* limit the scope of the function
* clang-formatted
* removed limit on table entries set by AVLBL_DRB, replaced with MAX_DRBS_PER_UE
The function nr_sdap_ue_qfi2drb_config should do UL QoS flow to DRB mapping configuration
for a SDAP entity has already been established according to TS 37.324, 5.3 QoS flow to
DRB Mapping, 5.3.1 Configuration Procedures. It should handle both mapping rules to add and to remove.
To this purpose:
* Simplify function signature by passing the sdap config.
* Improve readability of the function.
* Move handling of sdap.mappedQFIs2ReleaseCount (in nr_reconfigure_sdap_entity)
inside the function.
* Simplify end-marker control PDU mapping function by removing unused
DRB ID input parameter (the function is fetching the DRB ID based on the input
map type)
* use int instead of legacy rb_id_t
* limit scope of functions whenever necessary
The goal of this function is to return the DRB ID mapped to the input QFI, for both DL and UL.
The function looks up the DRB that is mapped to the QFI, if no mapping rule exists
returns the default DRB. Returns 0 If no mapping and no default DRB exists for that QFI
The function should not update the stored mapping rules, that is done when receiving
a new SDAP configuration. In this function it was removed.
See TS 37.324, 5.2.1 Uplink
> If there is no stored QoS flow to DRB mapping rule for the QoS flow as specified in the subclause 5.3,
> map the SDAP SDU to the default DRB else, map the SDAP SDU to the DRB according to the stored QoS flow to DRB mapping rule.
* change function signature: pass the sdap_config_t
* update qfi2drb mapping when receiving a configuration for an already existing SDAP entity
* always update mapping rules, not only for default DRB
* use get_sdap_Config to process sdap_Config
* move SDAP config logic to the scope where it is relevant
* add SDAP entity direcly in RRC, not from PDCP
* replaced nr_pdcp_add_drbs with single add_drb call: it was no longer
efficient to keep it in the new logic. The addMod list can be looped directly in RRC.
* add specific function to add bearers from addMod list in E1, NSA, and UE
fix direct bugs of not used RU_RX_SLOT_DEPTH defined constant
with this commit, the gNB can work if we change RU_RX_SLOT_DEPTH to
another value than 4 but it remain not well designed
Initialize NCC=0 on NGAP Initial Context Setup (3GPP TS 33.501 §6.9.2.1.1)
The nhcc should be initialized to 0 upon Initial Context Setup.
Also, remove unused kgnb_ncc: nh_ncc is already there.
Closes#1008
[CI] Update the Push to DockerHub Stage
This MR addresses two cases:
1. Error Handling: Ensures subsequent Image Test Processes stages
continue to run even if the preceding Push to DockerHub stage fails
(applies when the condition is PUSH event and doBuild is true).
2. Introduces conditional logic to correctly handle multi-architecture
images: Images built for both AMD64 and Jetson ARMv8 (oai-gnb,
oai-nr-ue, oai-nr-cuup) use docker buildx imagetools for push to
DockerHub.
All other AMD64 images are pushed using standard Docker commands.
Related MR !3691
Add monolithic N2 handover test pipeline with B210 and Quectel
The goal of this MR is to provide an automated end-to-end N2 HO
validation with real RF (B210) and Quectel UE.
During the testing phase a post-HO assertion failure due to
uninitialized selected_plmn_identity was found: this was also fixed.
CI: Add monolithic N2 handover test pipeline (B210 + Quectel)
- New XML pipeline for N2 HO testing
- Docker Compose for two monolithic gNBs (gNB1/gNB2)
- Handover sequence: gNB1 → gNB2 → gNB1 with 5s controlled attenuation
(RC4DAT).
- Channel mapping: ch1-2 gNB1, ch3-4 gNB2
- Telnet server enabled for CI commands
- Clean-up/reset of attenuator state included
NGAP
- fix PLMN/cell location for Initial UE and Uplink NAS
- Prevents assertion in ngap_gNB_nas_uplink() due to uninitialized
selected_plmn_identity
- Initial UE Message: pass UE-selected PLMN and NR cell ID from RRC to
NGAP
- Uplink NAS Transport: use PLMN, TAC, and cell ID from the message
- Build NR CGI as gNB ID + cell ID
- Store UE-selected PLMN only in RRC UE context (for later NAS); stop
storing PLMN in NGAP UE context.
- PLMN validation when processing handover requests from the source gNB:
when PLMN validation fails, the target gNB now properly sends
NGAP_HANDOVER_FAILURE
- Store serving PLMN for later use in UE context
UE symbol based PDCCH receiver
This is a partial rebase/rewrite of !2895
The goal of this MR is to check how we can merge this.
The eventual result is stated in !2895. The way forward is to modify UE
RX procedures to work symbol by symbol by extracting the symbol loop out
of RX procedures. After all channels are modified this way, the main
thread can be modified to work symbol by symbol.
At this point only PDCCH was modified.
- Push both AMD64 & ARMv8 Jetson images together for images built on both using `docker buildx imagetools`
- Use standard 'docker pull and push' for images built only on AMD64.
Prevent assertion in ngap_gNB_nas_uplink() due to uninitialized selected_plmn_identity:
the selected_plmn_identity field was not being set during N2 handover,
causing the assertion ((plmn->mnc_digit_length == 3) || (plmn->mnc_digit_length == 2))
to fail when processing subsequent NAS messages. The issue is that the Serving PLMN
is not stored by RRC. During N2 mobility, RRC can get this info from GUAMI.
When receiving the Handover Request the target gNB knows from GUAMI
which serving PLMN is the AMF belonging to. In current design, allowed PLMNs
are stored in rrc.configuration. The incoming PLMN needs to be validate
against the PLMNs in the list, then stored in the UE context as Serving PLMN.
This change adds PLMN validation when processing handover requests from the source gNB.
The validation is needed because:
- Target gNB must verify that the PLMN from the GUAMI in the handover request
is allowed by its configuration before accepting the handover to prevent handover
to unsupported PLMNs.
- When PLMN validation fails, the target gNB now properly sends NGAP_HANDOVER_FAILURE
- UE Context must store serving PLMN for later use
This commit is removing the storage of selected PLMN in NGAP UE context.
We store the Serving PLMN in the RRC UE context instead.
The Selected PLMN is the PLMN that the UE chose (or was directed to) for registration
and it is sent in the RRCSetupComplete. This is different from the selected
PLMN mentioned in the NG INITIAL UE MESSAGE for network sharing.
Selected PLMN: determines which core network and AMF the UE is registered with
GUAMI = Identifies the serving AMF and includes the PLMN of that AMF
Serving PLMN: the PLMN that is currently serving the UE (e.g. contained in GUAMI)
The AMF’s PLMN may match the selected PLMN, or not (especially in network sharing or roaming).
Regardless, the UE always have a Serving PLMN.
Initial UE message does not have a TAI IE per se, but TAI is a mandatory
member of the mandatory UserLocationInformation CHOICE.
NR CGI is also mandatory and carried inside UserLocationInformation:
in network sharing, the PLMN ID in TAI takes on additional
significance: RAN is shared but CN are different, so in this case PLMN in TAI is
needed for the AMF route the message to the correct operator’s core.
If network sharing applies (e.g., shared RAN between PLMN-A and PLMN-B):
the UE or network may select PLMN-B instead, and that PLMN identity
is included in the Initial UE Message’s TAI IE.
Conclusion:
1) UE always sends the selected PLMN during the registration,
regardless of whether it is shared or not.
2) Selected PLMN Identity is an actual IE sent in the RRCSetupComplete
while in NGAP there's no Selected PLMN Identity IE, only PLMN Identity
IEs in both TAI and NR CGI. It is a subtle difference.
3) The serving PLMN of the UE needs to be stored in RRC UE Context for
later use in NAS procedures. e.g. at initial registration it matches
the Selected PLMN
4) No need to store PLMN in NGAP UE Context, params are passed by RRC
5) TAI and NR CGI, which contain the PLMN identity, are mandatory in
UserLocationInformation IE CHOICE, and should reflect current status
Changes
- Initial UE Message: pass UE-selected PLMN and NR cell id from RRC to NGAP
- Uplink NAS Transport: use PLMN, TAC, and cell id provided by the message;
- Build NR CGI from gNB ID + cell id
- Store UE-selected PLMN only in RRC UE context at NAS_FIRST_REQ for later
Uplink NAS, stop storing PLMN in NGAP UE context
- Add XML pipeline for N2 handover testing
- Add Docker compose for two monolithic gNBs
- Features:
* Two monolithic gNBs (gNB1, gNB2) with proper CU+DU parameters
* Gradual attenuation control using RC4DAT attenuator (5s duration)
* N2 handover sequence: gNB1 → gNB2 → gNB1
* Proper channel mapping: ch1-2 for gNB1, ch3-4 for gNB2
* Telnet server configuration for CI commands
* Handover-specific neighbor configuration
* Clean test state management with attenuator reset
Update based on !3645
Note: For some test configurations we still need to provide
ra_ResponseWindow, for more details, check commit message of
41d14b571c