Add monolithic N2 handover test pipeline with B210 and Quectel
The goal of this MR is to provide an automated end-to-end N2 HO
validation with real RF (B210) and Quectel UE.
During the testing phase a post-HO assertion failure due to
uninitialized selected_plmn_identity was found: this was also fixed.
CI: Add monolithic N2 handover test pipeline (B210 + Quectel)
- New XML pipeline for N2 HO testing
- Docker Compose for two monolithic gNBs (gNB1/gNB2)
- Handover sequence: gNB1 → gNB2 → gNB1 with 5s controlled attenuation
(RC4DAT).
- Channel mapping: ch1-2 gNB1, ch3-4 gNB2
- Telnet server enabled for CI commands
- Clean-up/reset of attenuator state included
NGAP
- fix PLMN/cell location for Initial UE and Uplink NAS
- Prevents assertion in ngap_gNB_nas_uplink() due to uninitialized
selected_plmn_identity
- Initial UE Message: pass UE-selected PLMN and NR cell ID from RRC to
NGAP
- Uplink NAS Transport: use PLMN, TAC, and cell ID from the message
- Build NR CGI as gNB ID + cell ID
- Store UE-selected PLMN only in RRC UE context (for later NAS); stop
storing PLMN in NGAP UE context.
- PLMN validation when processing handover requests from the source gNB:
when PLMN validation fails, the target gNB now properly sends
NGAP_HANDOVER_FAILURE
- Store serving PLMN for later use in UE context
UE symbol based PDCCH receiver
This is a partial rebase/rewrite of !2895
The goal of this MR is to check how we can merge this.
The eventual result is stated in !2895. The way forward is to modify UE
RX procedures to work symbol by symbol by extracting the symbol loop out
of RX procedures. After all channels are modified this way, the main
thread can be modified to work symbol by symbol.
At this point only PDCCH was modified.
Prevent assertion in ngap_gNB_nas_uplink() due to uninitialized selected_plmn_identity:
the selected_plmn_identity field was not being set during N2 handover,
causing the assertion ((plmn->mnc_digit_length == 3) || (plmn->mnc_digit_length == 2))
to fail when processing subsequent NAS messages. The issue is that the Serving PLMN
is not stored by RRC. During N2 mobility, RRC can get this info from GUAMI.
When receiving the Handover Request the target gNB knows from GUAMI
which serving PLMN is the AMF belonging to. In current design, allowed PLMNs
are stored in rrc.configuration. The incoming PLMN needs to be validate
against the PLMNs in the list, then stored in the UE context as Serving PLMN.
This change adds PLMN validation when processing handover requests from the source gNB.
The validation is needed because:
- Target gNB must verify that the PLMN from the GUAMI in the handover request
is allowed by its configuration before accepting the handover to prevent handover
to unsupported PLMNs.
- When PLMN validation fails, the target gNB now properly sends NGAP_HANDOVER_FAILURE
- UE Context must store serving PLMN for later use
This commit is removing the storage of selected PLMN in NGAP UE context.
We store the Serving PLMN in the RRC UE context instead.
The Selected PLMN is the PLMN that the UE chose (or was directed to) for registration
and it is sent in the RRCSetupComplete. This is different from the selected
PLMN mentioned in the NG INITIAL UE MESSAGE for network sharing.
Selected PLMN: determines which core network and AMF the UE is registered with
GUAMI = Identifies the serving AMF and includes the PLMN of that AMF
Serving PLMN: the PLMN that is currently serving the UE (e.g. contained in GUAMI)
The AMF’s PLMN may match the selected PLMN, or not (especially in network sharing or roaming).
Regardless, the UE always have a Serving PLMN.
Initial UE message does not have a TAI IE per se, but TAI is a mandatory
member of the mandatory UserLocationInformation CHOICE.
NR CGI is also mandatory and carried inside UserLocationInformation:
in network sharing, the PLMN ID in TAI takes on additional
significance: RAN is shared but CN are different, so in this case PLMN in TAI is
needed for the AMF route the message to the correct operator’s core.
If network sharing applies (e.g., shared RAN between PLMN-A and PLMN-B):
the UE or network may select PLMN-B instead, and that PLMN identity
is included in the Initial UE Message’s TAI IE.
Conclusion:
1) UE always sends the selected PLMN during the registration,
regardless of whether it is shared or not.
2) Selected PLMN Identity is an actual IE sent in the RRCSetupComplete
while in NGAP there's no Selected PLMN Identity IE, only PLMN Identity
IEs in both TAI and NR CGI. It is a subtle difference.
3) The serving PLMN of the UE needs to be stored in RRC UE Context for
later use in NAS procedures. e.g. at initial registration it matches
the Selected PLMN
4) No need to store PLMN in NGAP UE Context, params are passed by RRC
5) TAI and NR CGI, which contain the PLMN identity, are mandatory in
UserLocationInformation IE CHOICE, and should reflect current status
Changes
- Initial UE Message: pass UE-selected PLMN and NR cell id from RRC to NGAP
- Uplink NAS Transport: use PLMN, TAC, and cell id provided by the message;
- Build NR CGI from gNB ID + cell id
- Store UE-selected PLMN only in RRC UE context at NAS_FIRST_REQ for later
Uplink NAS, stop storing PLMN in NGAP UE context
- Add XML pipeline for N2 handover testing
- Add Docker compose for two monolithic gNBs
- Features:
* Two monolithic gNBs (gNB1, gNB2) with proper CU+DU parameters
* Gradual attenuation control using RC4DAT attenuator (5s duration)
* N2 handover sequence: gNB1 → gNB2 → gNB1
* Proper channel mapping: ch1-2 for gNB1, ch3-4 for gNB2
* Telnet server configuration for CI commands
* Handover-specific neighbor configuration
* Clean test state management with attenuator reset
1. Refactor PDCCH PHY functions to take rxdataF of one OFDM symbol and
produce LLR for each search space. The modified functions take
rxdataF in a different format than that produced by nr_slot_fep(). So
for now a memcpy is used to change the array structure. Once
nr_slot_fep() is modified, this memcpy will no longer be needed and
will be removed.
2. Modify DCI functions to decode DCI in the last PDCCH symbol and
inidcate to MAC once.
3. Fix PDCCH monitoring for start symbol > 0.
4. Fix multiple PDCCH monitoring within slot.
Co-authored-by: Sakthivel Velumani <mail@sakthi.me>
1.Create new funtion nr_symbol_fep() to do OFDM demod of one symbol on
all antennas. This is called by nr_slot_fep() for now. In the
upcoming MR, this function will be called directly after reading
each OFDM symbol from the radio.
2.Removed redundant memory alignment. DFT function performs memory
alignment if the input memory is not aligned.
Fixes for T-Tracer to work with NR-UE
Fixes to align NR UE events with their definitions in T_messages.txt and
match the expected format in the tracer GUI parser.
Also fixes DL SNR to work in tracer GUI.
Support beam index in OAI 7.2 Fronthaul Interface
This branch supports beam index in OAI 7.2 Fronthaul Interface.
- For CP DL (PDSCH), nBeamIndex of the corresponding prbMapElm is set
when sending IQ data in oran_fh_if4p5_south_out. nBeamIndex of the
corresponding prbMapElm is set when sending IQ data in
oran_fh_if4p5_south_out.
- For CP UL (PUSCH and PRACH), nBeamIndex of the corresponding prbMapElm
is set in oran_fh_if4p5_south_out.
In addition, it fixes a couple of issues
- XRAN hardcodes nBeamIndex of PRACH to zero. Modify XRAN to support
setting of nBeamIndex of PRACH and update xran F release patch.
- Fix the bug in calculating fh_config->neAxc where num_beams_period is
multiplified twice
Testing methodology: Use Benetel O_RU for testing even though it does
not support beamforming. With successful registration and data transfer,
one could check the pcap on the fronthaul interface to see if CP packets
are with the right beam index.
Results:
1. Verified that CP-packets for SSB, DCI, PDSCH, PRACH, PDSCH, PUSCH,
CSI-RS and SRS are with the right beam index
2. Verified that there is no side-effect on Benetel O_RU. UE could
register properly.
3. Verified 4 SSB with ssb_PositionsInBurst_Bitmap = 85. Could see SSB
and PRACH with 4 different indices.
Handle CP UL packet at xran_fx_tx_send_slot() instead of
xran_fh_rx_read_slot(), as the latter would set this information too
late (on reception on samples, but it needs to be filled in the CP
packet prior to reception).
Initialize ru_info structure with beam information, and set beams on TX
direction. Initialize the number of antennas for both RX/TX in both
cases for completeness.
1. Fix UE_PHY_PDSCH_IQ event
2. Fix UE_PHY_PDCCH_ENERGY event
3. Fix UE_PHY_PDSCH_ENERGY event
4. Fix UE_PHY_MEAS event
All fixes align NR UE events with their definitions in T_messages.txt and match the expected format in the tracer GUI parser.
Integration `2025.w42`
* !3623 Optimization of PDSCH precoding operation
* !3691 \[CI\] Ensure multi-arch DockerHub Push after successful image build
* !3696 asn1c doesn't follow c99 variables alias rules, it needs to be compiled this...
* !3685 Assign antenna ports correctly for 1 and 2 layers for aerial.
* !3495 Type0 PDSCH frequency allocation at L1 UE
* !3686 Remove NR L2 simulator code from UE
* !3693 Remove B200-specific clock-rate setting
* !3701 OAI UE: add shared RSRP Table 10.1.6.1-1 mapping function to helpers and adopt it RRC UE
* !3662 RRC UE file cleanup
* update doc/README.md
* !3608 use common scale channel functions for DLSCH and ULSCH
* !3694 fix non initialized DMRS port value in case of DCI00 at UE
* !3702 Extend F1 rfsim CI test
* !3704 remove unused global queues, dead code
* !3673 CI: Aerial: Add an UL-heavy pipeline test
* !3651 CI: Upgrade HO setup to use an attenuator
* !3695 CI: Upgrade Aerial setup to 25-2.1
Closes#940
See merge request oai/openairinterface5g!3700
CI: Upgrade Aerial setup to 25-2.1
The purpose of this MR is to upgrade the cuBB image in the Aerial setup to
release 25-2.1 and update the doc/Aerial_FAPI_Split_Tutorial.md accordingly.
CI: Upgrade HO setup to use an attenuator
The goal of this MR is to upgrade HO CI setup to include a digital attenuator
that will allow us to trigger handover by attenuating the signals on the DUs.
Doing this before using set_master_clock_rate() on the B200 seems to
invalidate synchronization setting.
[HW] USRP clock set to 1759836386.000000 sec
[...]
[HW] current pps at 3.286750, starting streaming at 4.286750
In other words, the current time setting was reset. With this change
now, we see
[HW] USRP clock set to 1759929873.000000 sec
[...]
[HW] current pps at 1759929873.000000, starting streaming at 1759929874.000000
This is because changing clock sources (I assume setting the master
clock rate impacts the clock) can result in changing the time. From the
documentation of [1]:
> Note: When changing clock sources, a previously set time will most
> likely be lost. It is recommended to set the time after changing the
> clock source. Otherwise, an unexpected time may line up with future PPS
> edges.
[1] https://files.ettus.com/manual/classuhd_1_1usrp_1_1multi__usrp.html#a99254abfa5259b70a020e667eee619b9
- main.py: replace %%workspace%% with CONTAINERS.eNBSourceCodePath in Custom_Command and Custom_Script
Co-authored-by: Guido Casati <hello@guidocasati.com>
- Add band mismatch check in valid_du_in_neighbour_configs function
- Ensures neighbor cell band matches serving cell band
- Prevents invalid neighbor configurations for handover
The code only checked that Msg3 would be scheduled during UL, but in
some combinations, e.g., with DSUUU, the current slot can very well be
UL as well => we would schedule DCI in UL slot.
Update cuBB image to cubb-build:25-2.1_srs-ul-heavy (release 25-2.1 with
changes in the L1 config to test heavy ul)
Co-authored-by: Reem Bahsoun <reem.bahsoun@openairinterface.org>